About: Importance of the counterion in optimization of a borate electrolyte system for analyses of anions in samples with complex matrices performed by capillary zone electrophoresis     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • Borate buffers are common background electrolytes for analyses of anions in capillary zone electrophoresis. Usually, sodium borate at a given pH is used and this specification seems to be sufficient for a successful analysis. In this paper, we show that free migration of OH- may deteriorate the analysis of a typical anionic analysis of clinical samples due to uncontrolled migration of OH- throughout the systems of analyzed zones and may damage the stacking of anionic analytes of interest. We have proven that the use of ammonium borate may remedy the situation where the presence of ammonium may selectively stop the free migration of OH- ions, slow down their effective mobility and bring their safe behavior resulting in reproducible stacking of clinically important anions. Results of real analyses of human serum samples confirmed the proposed method and proved that substitution of sodium for ammonium in borate buffers offers reliable analyses of clinical samples having chloride as the bulk component. Th
  • Borate buffers are common background electrolytes for analyses of anions in capillary zone electrophoresis. Usually, sodium borate at a given pH is used and this specification seems to be sufficient for a successful analysis. In this paper, we show that free migration of OH- may deteriorate the analysis of a typical anionic analysis of clinical samples due to uncontrolled migration of OH- throughout the systems of analyzed zones and may damage the stacking of anionic analytes of interest. We have proven that the use of ammonium borate may remedy the situation where the presence of ammonium may selectively stop the free migration of OH- ions, slow down their effective mobility and bring their safe behavior resulting in reproducible stacking of clinically important anions. Results of real analyses of human serum samples confirmed the proposed method and proved that substitution of sodium for ammonium in borate buffers offers reliable analyses of clinical samples having chloride as the bulk component. Th (en)
Title
  • Importance of the counterion in optimization of a borate electrolyte system for analyses of anions in samples with complex matrices performed by capillary zone electrophoresis
  • Importance of the counterion in optimization of a borate electrolyte system for analyses of anions in samples with complex matrices performed by capillary zone electrophoresis (en)
skos:prefLabel
  • Importance of the counterion in optimization of a borate electrolyte system for analyses of anions in samples with complex matrices performed by capillary zone electrophoresis
  • Importance of the counterion in optimization of a borate electrolyte system for analyses of anions in samples with complex matrices performed by capillary zone electrophoresis (en)
skos:notation
  • RIV/61989592:15310/04:00005826!RIV10-MSM-15310___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(GA203/02/0023), P(IAA4031401), S, Z(AV0Z4031919)
http://linked.open...iv/cisloPeriodika
  • 20
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 567508
http://linked.open...ai/riv/idVysledku
  • RIV/61989592:15310/04:00005826
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • background electrolyte; borate buffer, capillary zone electrophoresis; serum analysis; stacking; transient isotachophoresis (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • DE - Spolková republika Německo
http://linked.open...ontrolniKodProRIV
  • [BFE8B50DD8F9]
http://linked.open...i/riv/nazevZdroje
  • Electrophoresis
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 25
http://linked.open...iv/tvurceVysledku
  • Boček, Petr
  • Křivánková, Ludmila
  • Gebauer, Petr
  • Mrázková, Michaela
http://linked.open...n/vavai/riv/zamer
issn
  • 0173-0835
number of pages
http://localhost/t...ganizacniJednotka
  • 15310
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 48 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software