About: The advantages and limitations of impedance aggregometry in detection of heparin-induced thrombocytopenia.     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • BACKGROUND: Heparin-induced thrombocytopenia (HIT) represents a serious complication of heparin treatment. IgG antibodies binding platelet factor 4 (PF4) and heparin trigger the clinical manifestations of HIT. However, only a portion of the antibodies have the ability to activate platelets, and these can be identified by a platelet aggregation test (functional testing). Current methods HIPA and SRA are time-consuming and difficult if HIT is clinically suspected; therefore, numerous new methods have recently been developed. METHODS: To determine HIT, impedance aggregometry using the Multiplate analyzer (MEA) as heparin-induced aggregation techniques and the Technozym HIT Ig ELISA test were used. The MEA method uses sensitization of donor platelets with patient plasma in the presence of heparin at a concentration of 0.5 IU/mL. The results were compared with the ELISA test. RESULTS: We examined 190 patients at clinically intermediate and higher risk of HIT according to the 4T score. All samples were examined by the ELISA test and MEA, with positive samples being further confirmed by high-concentration heparin. The methodology was modified with respect to the dilution for high positive samples and assessment has been extended to an index of inhibition. CONCLUSIONS: In the studied group, we demonstrated that MEA has sufficient sensitivity and higher specificity. In the group of patients, 10.0% showed positive results by MEA as compared with 7.3% determined by ELISA. Unlike the ELISA methods of the same quality, MEA is more suitable for detecting platelet-activating HIT antibodies in practice.
  • BACKGROUND: Heparin-induced thrombocytopenia (HIT) represents a serious complication of heparin treatment. IgG antibodies binding platelet factor 4 (PF4) and heparin trigger the clinical manifestations of HIT. However, only a portion of the antibodies have the ability to activate platelets, and these can be identified by a platelet aggregation test (functional testing). Current methods HIPA and SRA are time-consuming and difficult if HIT is clinically suspected; therefore, numerous new methods have recently been developed. METHODS: To determine HIT, impedance aggregometry using the Multiplate analyzer (MEA) as heparin-induced aggregation techniques and the Technozym HIT Ig ELISA test were used. The MEA method uses sensitization of donor platelets with patient plasma in the presence of heparin at a concentration of 0.5 IU/mL. The results were compared with the ELISA test. RESULTS: We examined 190 patients at clinically intermediate and higher risk of HIT according to the 4T score. All samples were examined by the ELISA test and MEA, with positive samples being further confirmed by high-concentration heparin. The methodology was modified with respect to the dilution for high positive samples and assessment has been extended to an index of inhibition. CONCLUSIONS: In the studied group, we demonstrated that MEA has sufficient sensitivity and higher specificity. In the group of patients, 10.0% showed positive results by MEA as compared with 7.3% determined by ELISA. Unlike the ELISA methods of the same quality, MEA is more suitable for detecting platelet-activating HIT antibodies in practice. (en)
Title
  • The advantages and limitations of impedance aggregometry in detection of heparin-induced thrombocytopenia.
  • The advantages and limitations of impedance aggregometry in detection of heparin-induced thrombocytopenia. (en)
skos:prefLabel
  • The advantages and limitations of impedance aggregometry in detection of heparin-induced thrombocytopenia.
  • The advantages and limitations of impedance aggregometry in detection of heparin-induced thrombocytopenia. (en)
skos:notation
  • RIV/61989592:15110/14:33151355!RIV15-MSM-15110___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • S
http://linked.open...iv/cisloPeriodika
  • 8
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 1759
http://linked.open...ai/riv/idVysledku
  • RIV/61989592:15110/14:33151355
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • ELISA determination of HIT; functional test for detection HIT; heparin-induced trombocytopenia (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • DE - Spolková republika Německo
http://linked.open...ontrolniKodProRIV
  • [ED7A42B7B518]
http://linked.open...i/riv/nazevZdroje
  • Clinical Laboratory
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 60
http://linked.open...iv/tvurceVysledku
  • Indrák, Karel
  • Krčová, Věra
  • Procházková, Jana
  • Slavík, Luděk
  • Hluší, Antonín
  • Úlehlová, Jana
  • Kaletová, Markéta
  • Hrčková, Yvona
  • Svobodová, Gabriela
issn
  • 1433-6510
number of pages
http://bibframe.org/vocab/doi
  • 10.7754/Clin.Lab.2013.130740
http://localhost/t...ganizacniJednotka
  • 15110
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 49 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software