About: Determination of deposit thickness in natural gas cooler based on the measurements of gas cooling degree     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • An original method for estimating fouled deposit thickness on the inside surfaces of natural gas cooler tubes is presented. This method does not require opening and inspecting a cooler as it is based on the measurement of gas cooling degree, i.e. the gas temperature difference between the cooler inlet and discharge. The deposit layer on the internal heat transfer surfaces is of semi-liquid consistency and its thermal conductivity coefficient has not been investigated until now. This paper describes the experimental determination of the deposit thermal conductivity coefficient. This parameter enables determination of a cooler’s performance as a function of current deposit thickness. Practical application of the method is illustrated in the case of CH_R cooler working in the KS01 compressor station in Veľké Kapušany, Slovakia. For this type of cooler, a diagram for deposit thickness as a function of the gas cooling degree is presented.
  • An original method for estimating fouled deposit thickness on the inside surfaces of natural gas cooler tubes is presented. This method does not require opening and inspecting a cooler as it is based on the measurement of gas cooling degree, i.e. the gas temperature difference between the cooler inlet and discharge. The deposit layer on the internal heat transfer surfaces is of semi-liquid consistency and its thermal conductivity coefficient has not been investigated until now. This paper describes the experimental determination of the deposit thermal conductivity coefficient. This parameter enables determination of a cooler’s performance as a function of current deposit thickness. Practical application of the method is illustrated in the case of CH_R cooler working in the KS01 compressor station in Veľké Kapušany, Slovakia. For this type of cooler, a diagram for deposit thickness as a function of the gas cooling degree is presented. (en)
Title
  • Determination of deposit thickness in natural gas cooler based on the measurements of gas cooling degree
  • Determination of deposit thickness in natural gas cooler based on the measurements of gas cooling degree (en)
skos:prefLabel
  • Determination of deposit thickness in natural gas cooler based on the measurements of gas cooling degree
  • Determination of deposit thickness in natural gas cooler based on the measurements of gas cooling degree (en)
skos:notation
  • RIV/61989100:27360/11:86080019!RIV12-GA0-27360___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(GA106/07/0938)
http://linked.open...iv/cisloPeriodika
  • 11
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 193820
http://linked.open...ai/riv/idVysledku
  • RIV/61989100:27360/11:86080019
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • overall heat transfer coefficient; sediment thickness; cooler; natural gas (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • DE - Spolková republika Německo
http://linked.open...ontrolniKodProRIV
  • [EC665CA94A46]
http://linked.open...i/riv/nazevZdroje
  • Journal of Mechanical Science and Technology
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 25
http://linked.open...iv/tvurceVysledku
  • Příhoda, Miroslav
  • Čarnogurská, Mária
  • Molínek, Jiří
http://linked.open...ain/vavai/riv/wos
  • 000296926200025
issn
  • 1738-494X
number of pages
http://bibframe.org/vocab/doi
  • 10.1007/s12206-011-0702-7
http://localhost/t...ganizacniJednotka
  • 27360
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 77 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software