About: Intra-day and inter-day reliability of heart rate variability measurement     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
rdfs:seeAlso
Description
  • At present, analysis of heart rate variability (HRV) is becoming widely used as a clinical or research tool. Supported reliability studies for HRV measurement are, however, still limited. The main purpose was to perform an assessment of the absolute and relative reliability of HRV parameters from short-term recordings by means of orthoclinostatic stimulation and to investigate, whether there is a difference in repeating the retest immediately or after several days. The study group consisted of 99 participants (mean age 22 ± 1.24 years). Standard HRV indexes were computed: PT (total spectral power), PHF (high frequency spectral power), PLF (low frequency spectral power) and LF/HF. Absolute reliability was assessed by the standard error of measurement and 95% limits of agreement; relative reliability was assessed by the intraclass correlation coefficient. There was also an estimate of the sample size needed to detect the mean difference more equal 30% of the between-subject standard deviation. In conclusion, a large random variation (within individuals) of HRV parameters was revealed, regardless of whether the retest was repeated immediately or with an interruption. For most HRV parameters (particularly in the immediately repeated test-retest), however, random variation represents a limited portion of the between-subject variability.
  • At present, analysis of heart rate variability (HRV) is becoming widely used as a clinical or research tool. Supported reliability studies for HRV measurement are, however, still limited. The main purpose was to perform an assessment of the absolute and relative reliability of HRV parameters from short-term recordings by means of orthoclinostatic stimulation and to investigate, whether there is a difference in repeating the retest immediately or after several days. The study group consisted of 99 participants (mean age 22 ± 1.24 years). Standard HRV indexes were computed: PT (total spectral power), PHF (high frequency spectral power), PLF (low frequency spectral power) and LF/HF. Absolute reliability was assessed by the standard error of measurement and 95% limits of agreement; relative reliability was assessed by the intraclass correlation coefficient. There was also an estimate of the sample size needed to detect the mean difference more equal 30% of the between-subject standard deviation. In conclusion, a large random variation (within individuals) of HRV parameters was revealed, regardless of whether the retest was repeated immediately or with an interruption. For most HRV parameters (particularly in the immediately repeated test-retest), however, random variation represents a limited portion of the between-subject variability. (en)
Title
  • Intra-day and inter-day reliability of heart rate variability measurement
  • Intra-day and inter-day reliability of heart rate variability measurement (en)
skos:prefLabel
  • Intra-day and inter-day reliability of heart rate variability measurement
  • Intra-day and inter-day reliability of heart rate variability measurement (en)
skos:notation
  • RIV/61989100:27240/13:86088639!RIV14-MSM-27240___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • S
http://linked.open...iv/cisloPeriodika
  • 2
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 80942
http://linked.open...ai/riv/idVysledku
  • RIV/61989100:27240/13:86088639
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • orthoclinostatic; test-retest; autonomic nervous system; reliability; heart rate variability (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • GB - Spojené království Velké Británie a Severního Irska
http://linked.open...ontrolniKodProRIV
  • [D95D461F3889]
http://linked.open...i/riv/nazevZdroje
  • Journal of Sports Sciences
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 31
http://linked.open...iv/tvurceVysledku
  • Litschmannová, Martina
  • Cipryan, Lukáš
http://linked.open...ain/vavai/riv/wos
  • 000314351400004
issn
  • 0264-0414
number of pages
http://bibframe.org/vocab/doi
  • 10.1080/02640414.2012.721931
http://localhost/t...ganizacniJednotka
  • 27240
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 48 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software