About: Invasive blood pressure curves simulation device     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • Patient monitor modules have various inputs for vital function measurement. We can practice many of these measurements with some students in the laboratory of biomedical engineering. However, invasive blood pressure (IBP) measurement demonstration is impossible. This paper is dealing with design and realization of a programmable invasive blood pressure simulator. This device is able to generate programmable behavior of voltage signal with correspond to blood pressure curve. The user communication interface of the device allows choosing the type of generated signal by LCD and 4 push buttons. The wide spectrums of generated signals, which correspond to physiological or pathological blood pressure curves, are stored in a user programmable memory. The output connectors of the device can be directly connected to a patient monitor IBP module input. Invasive blood pressure measurement simulation for educational purposes and calibrating the patients monitors are the general usages of the developed device
  • Patient monitor modules have various inputs for vital function measurement. We can practice many of these measurements with some students in the laboratory of biomedical engineering. However, invasive blood pressure (IBP) measurement demonstration is impossible. This paper is dealing with design and realization of a programmable invasive blood pressure simulator. This device is able to generate programmable behavior of voltage signal with correspond to blood pressure curve. The user communication interface of the device allows choosing the type of generated signal by LCD and 4 push buttons. The wide spectrums of generated signals, which correspond to physiological or pathological blood pressure curves, are stored in a user programmable memory. The output connectors of the device can be directly connected to a patient monitor IBP module input. Invasive blood pressure measurement simulation for educational purposes and calibrating the patients monitors are the general usages of the developed device (en)
Title
  • Invasive blood pressure curves simulation device
  • Invasive blood pressure curves simulation device (en)
skos:prefLabel
  • Invasive blood pressure curves simulation device
  • Invasive blood pressure curves simulation device (en)
skos:notation
  • RIV/61989100:27240/11:86085779!RIV13-MSM-27240___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • S
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 205637
http://linked.open...ai/riv/idVysledku
  • RIV/61989100:27240/11:86085779
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Wide spectrum; Voltage signals; User communication; Simulation device; Push buttons; Programmable memory; Pressure curve; Function measurements (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [AFD2E8C07769]
http://linked.open...v/mistoKonaniAkce
  • Sharjah
http://linked.open...i/riv/mistoVydani
  • New York
http://linked.open...i/riv/nazevZdroje
  • 2011 1st Middle East Conference on Biomedical Engineering, MECBME 2011
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Penhaker, Marek
  • Černohorský, Jindřich
  • Kijonka, Jan
http://linked.open...vavai/riv/typAkce
http://linked.open.../riv/zahajeniAkce
number of pages
http://bibframe.org/vocab/doi
  • 10.1109/MECBME.2011.5752098
http://purl.org/ne...btex#hasPublisher
  • IEEE
https://schema.org/isbn
  • 978-1-4244-7000-6
http://localhost/t...ganizacniJednotka
  • 27240
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software