| - Operation of the drives may be negatively affected by non-standard conditions in the power network such as voltage unbalance, which may arise in three-phase power networks. The unbalance can be caused by a failure in the network or by unbalanced load in the vicinity of the affected drive. Unsymmetrical voltages at the input of a voltage source inverter cause pulsations in the DC link voltage when not properly taken care of. This may result in reduced power capabilities of the drive. The paper deals with the methods to address this problem and with the limitations placed on the drive when operated from the unbalanced voltage supply.
- Operation of the drives may be negatively affected by non-standard conditions in the power network such as voltage unbalance, which may arise in three-phase power networks. The unbalance can be caused by a failure in the network or by unbalanced load in the vicinity of the affected drive. Unsymmetrical voltages at the input of a voltage source inverter cause pulsations in the DC link voltage when not properly taken care of. This may result in reduced power capabilities of the drive. The paper deals with the methods to address this problem and with the limitations placed on the drive when operated from the unbalanced voltage supply. (en)
- Činnost elektrických pohonů může být nepříznivě ovlivněna nestandardními podmínkami v elektrické síti, jako je napěťová nesymetrie, která se může vyskytnout v trojfázových sítích. Tato nesymetrie může být způsobena poruchou v síti nebo připojením nesymetrické zátěže do sítě v blízkosti vyšetřovaného pohonu. Nesymetrické napájení napěťového měniče způsobuje, pokud nejsou přijata vhodná protiopatření, pulzace napětí ve stejnosměrném meziobvodu. Tím může být snížena výkonová zatižitelnost pohonu. Článek se zabývá zejména omezeními, která vznikají při napájení pohonu nesymetrickým napětím. (cs)
|
Title
| - Limitation of Adjustable-Speed Drive Operation by Unbalanced Voltage Supply
- Limitation of Adjustable-Speed Drive Operation by Unbalanced Voltage Supply (en)
- Omezení chodu pohonu s proměnnými otáčkami způsobené nesymetrickým napájecím napětím (cs)
|
skos:prefLabel
| - Limitation of Adjustable-Speed Drive Operation by Unbalanced Voltage Supply
- Limitation of Adjustable-Speed Drive Operation by Unbalanced Voltage Supply (en)
- Omezení chodu pohonu s proměnnými otáčkami způsobené nesymetrickým napájecím napětím (cs)
|
skos:notation
| - RIV/61388998:_____/08:00315258!RIV09-AV0-61388998
|
http://linked.open...avai/riv/aktivita
| |
http://linked.open...avai/riv/aktivity
| - P(GA102/06/0215), Z(AV0Z20570509)
|
http://linked.open...vai/riv/dodaniDat
| |
http://linked.open...aciTvurceVysledku
| |
http://linked.open.../riv/druhVysledku
| |
http://linked.open...iv/duvernostUdaju
| |
http://linked.open...titaPredkladatele
| |
http://linked.open...dnocenehoVysledku
| |
http://linked.open...ai/riv/idVysledku
| - RIV/61388998:_____/08:00315258
|
http://linked.open...riv/jazykVysledku
| |
http://linked.open.../riv/klicovaSlova
| - unbalanced voltage supply; DC-link voltage pulsations; variable-speed drive (en)
|
http://linked.open.../riv/klicoveSlovo
| |
http://linked.open...ontrolniKodProRIV
| |
http://linked.open...v/mistoKonaniAkce
| |
http://linked.open...i/riv/mistoVydani
| |
http://linked.open...i/riv/nazevZdroje
| - Proceedings of the International Conference on Electrical Machines - ICEM 2008
|
http://linked.open...in/vavai/riv/obor
| |
http://linked.open...ichTvurcuVysledku
| |
http://linked.open...cetTvurcuVysledku
| |
http://linked.open...vavai/riv/projekt
| |
http://linked.open...UplatneniVysledku
| |
http://linked.open...iv/tvurceVysledku
| - Bendl, Jiří
- Chomát, Miroslav
- Schreier, Luděk
|
http://linked.open...vavai/riv/typAkce
| |
http://linked.open.../riv/zahajeniAkce
| |
http://linked.open...n/vavai/riv/zamer
| |
number of pages
| |
http://purl.org/ne...btex#hasPublisher
| |
https://schema.org/isbn
| |