About: Pulse wave velocity in elastic tube     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • The velocity of the pulse wave in blood vessels is one of the important hemodynamical parameters to detect health condition or a degree of damage of a diseased artery. To understand the problem, the physiological values must be known. In our laboratory, the velocity of pulse wave in elastic tubes and arteries is measured in vitro by non-invasive method. The method is based on optical measurements of displacement of the pulsating tube wall. A crash test camera with high frame rate of 1000 Hz (fps) was used. The frame rate of 1000 Hz proved to be sufficient to register the high velocities of the pulse wave. The obtained data were evaluated by several methods and compared. The measured pulse wave velocities ranged from 4.5 to 6 m/s, thus in the same order of magnitude as values based on theoretical calculations and physiological values published in literature. However, for more precise data analysis, more experimental data (longer optical record) is recommended.
  • The velocity of the pulse wave in blood vessels is one of the important hemodynamical parameters to detect health condition or a degree of damage of a diseased artery. To understand the problem, the physiological values must be known. In our laboratory, the velocity of pulse wave in elastic tubes and arteries is measured in vitro by non-invasive method. The method is based on optical measurements of displacement of the pulsating tube wall. A crash test camera with high frame rate of 1000 Hz (fps) was used. The frame rate of 1000 Hz proved to be sufficient to register the high velocities of the pulse wave. The obtained data were evaluated by several methods and compared. The measured pulse wave velocities ranged from 4.5 to 6 m/s, thus in the same order of magnitude as values based on theoretical calculations and physiological values published in literature. However, for more precise data analysis, more experimental data (longer optical record) is recommended. (en)
  • Rychlost pulzní vlny v cévách je jedním z důležitých hemodynamických parametrů pro odhad zdravotního stavu nebo rozsahu poškození cév. Pro pochopení tohoto problému musí být známé fyziologické vlastnosti cév. V naší laboratoři je zkoumána rychlost pulzní vlny v pružných elastických latexových trubicích a tepnách..Metoda je založená na snímání obrazu pulzující trubice, měřeních posunutí stěny trubice vlivem průchodu pulzní vlny. Byla použita vysokofrekvenční kamera se snímací frekvenci 1000 snímků/s. Získaná data byla analyzovány několika metodami a bylo provedeno porovnání výsledků. Změřené rychlosti pulzní vlny byly v rozsahu od 4.5 až 6 m/s. Jsou ve stejném řádu jako teoreticky vypočtené rychlosti a fyziologické hodnoty z literatury. Pro přesnější vyhodnoceni experimentů je vhodné získat vetší počet experimentálních dat. (cs)
Title
  • Pulse wave velocity in elastic tube
  • Pulse wave velocity in elastic tube (en)
  • Rychlost pulzní vlny v elastické trubici (cs)
skos:prefLabel
  • Pulse wave velocity in elastic tube
  • Pulse wave velocity in elastic tube (en)
  • Rychlost pulzní vlny v elastické trubici (cs)
skos:notation
  • RIV/61388998:_____/06:00047494!RIV07-AV0-61388998
http://linked.open.../vavai/riv/strany
  • 484;488
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(GA106/04/1181), Z(AV0Z20760514)
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 496059
http://linked.open...ai/riv/idVysledku
  • RIV/61388998:_____/06:00047494
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • biomechanics; elastic tube; pulse wave velocity (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [0C85283E33E8]
http://linked.open...v/mistoKonaniAkce
  • Lanzarote
http://linked.open...i/riv/mistoVydani
  • Lanzarote
http://linked.open...i/riv/nazevZdroje
  • The 25th IASTED International Conference on Modelling, Identification, and Control
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Chlup, Hynek
  • Konvičková, S.
  • Kubový, P.
  • Žitný, R.
  • Macková, H.
  • Vilímek, M.
http://linked.open...vavai/riv/typAkce
http://linked.open.../riv/zahajeniAkce
http://linked.open...n/vavai/riv/zamer
number of pages
http://purl.org/ne...btex#hasPublisher
  • IASTED
https://schema.org/isbn
  • 0-88986-551-5
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 77 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software