About: Evolution of the mock-line of cardiovascular system circuit     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • Simulation line of cardiovascular systém will be designed for setting velocity pulse wave in inserted sample of vein, thinwall tube and identification material properties of wall sample. This is a systemic circuit. 5 circuits were created in which were compared two possible simulations systemic resistance working on different principle. It was observed behaviour of individual line elements and their mutual influence. Done experiments shown optimal arranging of line elements.
  • Simulation line of cardiovascular systém will be designed for setting velocity pulse wave in inserted sample of vein, thinwall tube and identification material properties of wall sample. This is a systemic circuit. 5 circuits were created in which were compared two possible simulations systemic resistance working on different principle. It was observed behaviour of individual line elements and their mutual influence. Done experiments shown optimal arranging of line elements. (en)
  • Simulační linka kardiovaskulárního systému je koncipovaná pro stanovení rychlosti průchodu pulsní vlny vloženým vzorkem cévy, tenkostěnné elastické trubice a identifikace materiálových vlastností stěny vzorku. Jde o systémový okruh. Bylo sestaveno 5 testovacích okruhů ve kterých byly porovnány dvě možnosti simulace systémového odporu, pracující na odlišném principu. Bylo sledováno chování jednotlivých prvku linky a jejich vzájemné ovlivňování se. Provedené experimenty určily optimální uspořádání prvků linky. (cs)
Title
  • Evolution of the mock-line of cardiovascular system circuit
  • Evolution of the mock-line of cardiovascular system circuit (en)
  • Vývoj simulační linky okruhu kardiovaskulárního systému (cs)
skos:prefLabel
  • Evolution of the mock-line of cardiovascular system circuit
  • Evolution of the mock-line of cardiovascular system circuit (en)
  • Vývoj simulační linky okruhu kardiovaskulárního systému (cs)
skos:notation
  • RIV/61388998:_____/04:00103706!RIV/2005/GA0/A51005/N
http://linked.open.../vavai/riv/strany
  • 36;43
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(GA106/04/1181), Z(AV0Z2076919)
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 563464
http://linked.open...ai/riv/idVysledku
  • RIV/61388998:_____/04:00103706
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • experimental circuit of the cardiovascular system;analysis of the pressure logging;optimalization arrangement of the experimental circuit (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [9F56D6CD934E]
http://linked.open...v/mistoKonaniAkce
  • Svratka
http://linked.open...i/riv/mistoVydani
  • Praha
http://linked.open...i/riv/nazevZdroje
  • Engineering mechanics 2004
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Chlup, Hynek
  • Konvičková, S.
http://linked.open...vavai/riv/typAkce
http://linked.open.../riv/zahajeniAkce
http://linked.open...n/vavai/riv/zamer
number of pages
http://purl.org/ne...btex#hasPublisher
  • Ústav termomechaniky AV ČR
https://schema.org/isbn
  • 80-85918-88-9
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software