About: Characterization of DESI-FTICR mass spectrometry – from ECD to accurate mass tissue analysis     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • Implementation of desorption electrospray ionization (DESI) technique on a 9.4 T Fourier transform ion cyclotron resonance mass spectrometer (FTICR) is described. Desorption electrospray technique is capable of the direct investigation of natural samples without any means of sample preparation or chromatographic separation. Since the DESI mass spectra of natural samples are very complex due to the lack of pre-separation or clean-up, the ideal mass spectrometric analyzer for these applications is a high-resolution instrument such as FTICR mass spectrometer. DESI was implemented by constructing an electronically controlled source framework comprising six linear moving stages and one rotating stage. Three dimensional linear stage was used to accommodate samples, while another 3D linear stage equipped with rotating stage was used as a spray mount. Modified electrosonic sprayer was used as a primary electrospray device
  • Implementation of desorption electrospray ionization (DESI) technique on a 9.4 T Fourier transform ion cyclotron resonance mass spectrometer (FTICR) is described. Desorption electrospray technique is capable of the direct investigation of natural samples without any means of sample preparation or chromatographic separation. Since the DESI mass spectra of natural samples are very complex due to the lack of pre-separation or clean-up, the ideal mass spectrometric analyzer for these applications is a high-resolution instrument such as FTICR mass spectrometer. DESI was implemented by constructing an electronically controlled source framework comprising six linear moving stages and one rotating stage. Three dimensional linear stage was used to accommodate samples, while another 3D linear stage equipped with rotating stage was used as a spray mount. Modified electrosonic sprayer was used as a primary electrospray device (en)
  • Na Mikrobiologickém ústavu AV ČR v Praze byl nadesignován, zkonstruován a ozkoušen unikátní iontový zdroj pro iontový cyklotron. Pracuje na principu desorpčního elektrospreje a bude dále zkoušen pro klinické aplikace, zvláště pro měření tkání, celé krve případně dalších tělních tekutin. Technika se může prosadit v lékařské diagnostice, neboť zcela odbourává doposavadní nutnost biologické vzorky zpracovávat (homogenizovat, odsolovat, čistit). (cs)
Title
  • Characterization of DESI-FTICR mass spectrometry – from ECD to accurate mass tissue analysis
  • Popis DESI-FTICR-od ECD ke tkáňová analýze s přesnou hmotností (cs)
  • Characterization of DESI-FTICR mass spectrometry – from ECD to accurate mass tissue analysis (en)
skos:prefLabel
  • Characterization of DESI-FTICR mass spectrometry – from ECD to accurate mass tissue analysis
  • Popis DESI-FTICR-od ECD ke tkáňová analýze s přesnou hmotností (cs)
  • Characterization of DESI-FTICR mass spectrometry – from ECD to accurate mass tissue analysis (en)
skos:notation
  • RIV/61388971:_____/08:00313035!RIV09-AV0-61388971
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(GA203/07/0765), P(LC07017), Z(AV0Z50200510), Z(MSM6198959216)
http://linked.open...iv/cisloPeriodika
  • 12
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 359581
http://linked.open...ai/riv/idVysledku
  • RIV/61388971:_____/08:00313035
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • desorption electrospray; ion cyclotron resonance; lipids (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • GB - Spojené království Velké Británie a Severního Irska
http://linked.open...ontrolniKodProRIV
  • [980217190273]
http://linked.open...i/riv/nazevZdroje
  • Journal of Mass Spectrometry
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 42
http://linked.open...iv/tvurceVysledku
  • Novák, Petr
  • Havlíček, Vladimír
  • Lemr, K.
  • Kobliha, Václav
  • Ševčík, Karel
  • Kruppa, G.
  • Takats, Z.
http://linked.open...ain/vavai/riv/wos
  • 000253690000005
http://linked.open...n/vavai/riv/zamer
issn
  • 1076-5174
number of pages
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 75 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software