About: Dual detector calibration of PE-ELAN inductively coupled plasma mass spectrometers     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • Cross-calibration of dual-stage detector is a very important procedure that enables extension of a dynamic range of an inductively coupled plasma mass spectrometer. A calibration procedure based on the measurements of the intensities of argon plasma ions and matrix ions protects the spectrometer against contaminations; however, it can lead to the misinterpretation of the measured data, especially in the high atomic mass region. Calibration procedures based on the measurement of the intensities of argon plasma and matrix ions and of metal ions were mutually compared. Exemplary determination results for manganese (0-200 ng/mL), cesium (0-50 ng/mL) and lead (0-100 ng/mL) showed that only the dual detector calibration based on metal ions intensities measurements gives linear calibration plots.
  • Cross-calibration of dual-stage detector is a very important procedure that enables extension of a dynamic range of an inductively coupled plasma mass spectrometer. A calibration procedure based on the measurements of the intensities of argon plasma ions and matrix ions protects the spectrometer against contaminations; however, it can lead to the misinterpretation of the measured data, especially in the high atomic mass region. Calibration procedures based on the measurement of the intensities of argon plasma and matrix ions and of metal ions were mutually compared. Exemplary determination results for manganese (0-200 ng/mL), cesium (0-50 ng/mL) and lead (0-100 ng/mL) showed that only the dual detector calibration based on metal ions intensities measurements gives linear calibration plots. (en)
Title
  • Dual detector calibration of PE-ELAN inductively coupled plasma mass spectrometers
  • Dual detector calibration of PE-ELAN inductively coupled plasma mass spectrometers (en)
skos:prefLabel
  • Dual detector calibration of PE-ELAN inductively coupled plasma mass spectrometers
  • Dual detector calibration of PE-ELAN inductively coupled plasma mass spectrometers (en)
skos:notation
  • RIV/60461373:22340/09:00022531!RIV10-MSM-22340___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • Z(MSM6046137307)
http://linked.open...iv/cisloPeriodika
  • 6
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 311441
http://linked.open...ai/riv/idVysledku
  • RIV/60461373:22340/09:00022531
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Mass spectrometry; calibration; ion detection (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • PL - Polská republika
http://linked.open...ontrolniKodProRIV
  • [3E97455E835F]
http://linked.open...i/riv/nazevZdroje
  • Chemia Analityczna
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 54
http://linked.open...iv/tvurceVysledku
  • Koplík, Richard
  • Mestek, Oto
http://linked.open...n/vavai/riv/zamer
issn
  • 0009-2223
number of pages
http://localhost/t...ganizacniJednotka
  • 22340
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 47 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software