  • The work was aimed at the evaluation of a cleanliness of pharmaceutical equipments after the end of the production and subsequent cleaning process. The influence of a dirty-hold time, a time interval between the end of the production period and the beginning of the cleaning process on its efficiency and the cleanliness of the equipment has been studied. The evaluation was performed for commercial tablet antihypertensive formulation with API losartan potassium. Sampling was carried out by a wet-swabbing method from the equipments and consequently obtained samples were analytically evaluated using HPLC. In the production of the concerned pharmaceutical, it has been found that the cleaning process is properly designed and validated. Despite the concentration of losartan in swabs from the equipment was in all cases within the limits of acceptance criteria, the effect of the dirty-hold time was proved. In the equipments with long hold-time period, the monitored substance was found in substantially higher concentrations.
  • The work was aimed at the evaluation of a cleanliness of pharmaceutical equipments after the end of the production and subsequent cleaning process. The influence of a dirty-hold time, a time interval between the end of the production period and the beginning of the cleaning process on its efficiency and the cleanliness of the equipment has been studied. The evaluation was performed for commercial tablet antihypertensive formulation with API losartan potassium. Sampling was carried out by a wet-swabbing method from the equipments and consequently obtained samples were analytically evaluated using HPLC. In the production of the concerned pharmaceutical, it has been found that the cleaning process is properly designed and validated. Despite the concentration of losartan in swabs from the equipment was in all cases within the limits of acceptance criteria, the effect of the dirty-hold time was proved. In the equipments with long hold-time period, the monitored substance was found in substantially higher concentrations. (en)
Title
  • Effect of dirty-hold time on cleaning process of pharmaceutical equipment
  • Effect of dirty-hold time on cleaning process of pharmaceutical equipment (en)
skos:prefLabel
  • Effect of dirty-hold time on cleaning process of pharmaceutical equipment
  • Effect of dirty-hold time on cleaning process of pharmaceutical equipment (en)
skos:notation
  • RIV/60461373:22310/13:43896478!RIV14-MSM-22310___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • I
http://linked.open...iv/cisloPeriodika
  • 1
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 71473
http://linked.open...ai/riv/idVysledku
  • RIV/60461373:22310/13:43896478
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • fluid dryer; granulator; wet-swabs; Cleaning validation (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • GB - Spojené království Velké Británie a Severního Irska
http://linked.open...ontrolniKodProRIV
  • [6EB298D94DB8]
http://linked.open...i/riv/nazevZdroje
  • Pharmaceutical Development and Technology
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 18
http://linked.open...iv/tvurceVysledku
  • Zámostný, Petr
  • Patera, Jan
  • Bělohlav, Zdeněk
  • Vltavský, Zdeněk
  • Štípková, Gabriela
http://linked.open...ain/vavai/riv/wos
  • 000312008200028
issn
  • 1083-7450
number of pages
http://bibframe.org/vocab/doi
  • 10.3109/10837450.2012.726997
http://localhost/t...ganizacniJednotka
  • 22310
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 48 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software