About: Application of non-contact and contact temperature measurement     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • By solving applications of electrothermic diagnostic is an important factor to understand the distribution of temperature fields device changing in time. Methods for their determination are the contact and noncontact, each of them has advantages and disadvantages in different applications. Can be develop own devices that are just created for the given application and analyze the temperature field with the characteristic parameters of the machine or drive. Devices must comply with high accuracy and stability of the measured temperature. At the contact of measurement, which is used frequently in long-term measurements, it is necessary to compensate for the effects of interference wires and transient effects. For non-contact measurement is a fundamental problem of determining the emissivity of the measured surface and ensure the well-known conditions for measurement in relation to detection and set the constant measured load drive in mobile applications. (en)
  • Při návrhu a dimenzování zařízení se musí brát v úvahu mechanické přetížení systému, které obvykle vede ke zvýšení teploty objektu. Při nadměrném zvyšování teploty může dojít až k destrukci zařízení. Mechanické přetížení systému může být způsobeno přetížením nebo poškozením kluzných a ložiskových pouzder. Na základě měření teploty kritických částí lze provádět včasné výměny poškozených objektů. Lze aplikovat i část prediktivní údržby systému.
  • Při návrhu a dimenzování zařízení se musí brát v úvahu mechanické přetížení systému, které obvykle vede ke zvýšení teploty objektu. Při nadměrném zvyšování teploty může dojít až k destrukci zařízení. Mechanické přetížení systému může být způsobeno přetížením nebo poškozením kluzných a ložiskových pouzder. Na základě měření teploty kritických částí lze provádět včasné výměny poškozených objektů. Lze aplikovat i část prediktivní údržby systému. (cs)
Title
  • Application of non-contact and contact temperature measurement (en)
  • Aplikace bezdotykového a dotykového měření teploty
  • Aplikace bezdotykového a dotykového měření teploty (cs)
skos:prefLabel
  • Application of non-contact and contact temperature measurement (en)
  • Aplikace bezdotykového a dotykového měření teploty
  • Aplikace bezdotykového a dotykového měření teploty (cs)
skos:notation
  • RIV/60460709:41310/13:59922!RIV14-MSM-41310___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • S
http://linked.open...iv/cisloPeriodika
  • 1
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 61538
http://linked.open...ai/riv/idVysledku
  • RIV/60460709:41310/13:59922
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Thermal conductivity, thermocouple, temperature, sensor, ZigBee (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • CZ - Česká republika
http://linked.open...ontrolniKodProRIV
  • [031A76813E04]
http://linked.open...i/riv/nazevZdroje
  • Agritech Science
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 13
http://linked.open...iv/tvurceVysledku
  • Hromasová, Monika
  • Künzel, Gunnar
  • Linda, Miloslav
http://linked.open...ain/vavai/riv/wos
  • 0
issn
  • 1802-8942
number of pages
http://localhost/t...ganizacniJednotka
  • 41310
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software