About: Development of an Automated Tension Infi ltrometer for Field Use     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • Tension infiltrometry is a useful in situ technique that is commonly used to determine hydraulic conductivity of the soil near saturation; however, the measurements are time consuming and costly. The aim of this study was to develop a fully automated tension infiltrometer for field use based on already existing designs. Differential pressure transducers were used to automate water level measurements, and the tension settings were automated by a set of solenoid valves. The effects of different design parameters on water level measurement fluctuations created by bubble disturbances (noise) were studied in the laboratory. The differential transducer provided less noisy measurements than the single transducer. The measurement noise was significantly smaller when a large-diameter reservoir was used. The measurement noise was further reduced by using a reservoir system made of two tubes of different diameters slotted into each other. The effect of an increasing flow rate on the water level fluctuations was
  • Tension infiltrometry is a useful in situ technique that is commonly used to determine hydraulic conductivity of the soil near saturation; however, the measurements are time consuming and costly. The aim of this study was to develop a fully automated tension infiltrometer for field use based on already existing designs. Differential pressure transducers were used to automate water level measurements, and the tension settings were automated by a set of solenoid valves. The effects of different design parameters on water level measurement fluctuations created by bubble disturbances (noise) were studied in the laboratory. The differential transducer provided less noisy measurements than the single transducer. The measurement noise was significantly smaller when a large-diameter reservoir was used. The measurement noise was further reduced by using a reservoir system made of two tubes of different diameters slotted into each other. The effect of an increasing flow rate on the water level fluctuations was (en)
Title
  • Development of an Automated Tension Infi ltrometer for Field Use
  • Development of an Automated Tension Infi ltrometer for Field Use (en)
skos:prefLabel
  • Development of an Automated Tension Infi ltrometer for Field Use
  • Development of an Automated Tension Infi ltrometer for Field Use (en)
skos:notation
  • RIV/60460709:41210/09:30823!RIV10-MZE-41210___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(1G58095), Z(MSM6046070901)
http://linked.open...iv/cisloPeriodika
  • 3
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 310036
http://linked.open...ai/riv/idVysledku
  • RIV/60460709:41210/09:30823
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Automated tension infiltrometer; design factors testing; field use (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • US - Spojené státy americké
http://linked.open...ontrolniKodProRIV
  • [60F333A97DDE]
http://linked.open...i/riv/nazevZdroje
  • Vadose Zone Journal
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 8
http://linked.open...iv/tvurceVysledku
  • Matula, Svatopluk
  • Špongrová, Kamila
  • Kechavarzi, Cedric
  • Dresser, M.
  • Godwin, Richard J.
http://linked.open...n/vavai/riv/zamer
issn
  • 1539-1663
number of pages
http://localhost/t...ganizacniJednotka
  • 41210
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 110 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software