About: Discard volume necessary for elimination of heparin flush effect on thromboelastography     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • Heparin is commonly used to prevent obstruction of indwelling arterial catheters with blood clots. It is known to affect the outcomes of analysis of coagulation parameters with thromboelastography (TEG); therefore, it has been recommended to neutralize its effect with heparinase. However, heparinase may also neutralize the effect of low molecular weight heparin and endogenous heparinoids present in critically ill patients. The aim of this study was to evaluate the minimal discard blood volume needed to eliminate the effect of heparin flush on TEG parameters without the use of heparinase. Coagulation parameters were evaluated with kaolin-activated TEG. We found an increase in coagulation (reflecting the heparin elimination)with the increasing discard volume between 1 and 4 ml. This was obvious from an increase in a angle and maximal amplitude of the measured clot and a decrease in R and time to maximal amplitude of the measured clot (P<0.001).
  • Heparin is commonly used to prevent obstruction of indwelling arterial catheters with blood clots. It is known to affect the outcomes of analysis of coagulation parameters with thromboelastography (TEG); therefore, it has been recommended to neutralize its effect with heparinase. However, heparinase may also neutralize the effect of low molecular weight heparin and endogenous heparinoids present in critically ill patients. The aim of this study was to evaluate the minimal discard blood volume needed to eliminate the effect of heparin flush on TEG parameters without the use of heparinase. Coagulation parameters were evaluated with kaolin-activated TEG. We found an increase in coagulation (reflecting the heparin elimination)with the increasing discard volume between 1 and 4 ml. This was obvious from an increase in a angle and maximal amplitude of the measured clot and a decrease in R and time to maximal amplitude of the measured clot (P<0.001). (en)
Title
  • Discard volume necessary for elimination of heparin flush effect on thromboelastography
  • Discard volume necessary for elimination of heparin flush effect on thromboelastography (en)
skos:prefLabel
  • Discard volume necessary for elimination of heparin flush effect on thromboelastography
  • Discard volume necessary for elimination of heparin flush effect on thromboelastography (en)
skos:notation
  • RIV/60460709:41110/10:47958!RIV11-MSM-41110___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • S, V
http://linked.open...iv/cisloPeriodika
  • 2
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 254564
http://linked.open...ai/riv/idVysledku
  • RIV/60460709:41110/10:47958
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • arterial blood sampling, coagulation, discard volume, heparin flush, kaolin-activated, thromboelastography (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • US - Spojené státy americké
http://linked.open...ontrolniKodProRIV
  • [E368CC8F823D]
http://linked.open...i/riv/nazevZdroje
  • Blood Coagulation & Fibrinolysis
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 21
http://linked.open...iv/tvurceVysledku
  • Pacáková, Zuzana
  • Cvachovec, Karel
  • Durila, Miroslav
  • Kalinčík, Tomáš
http://linked.open...ain/vavai/riv/wos
  • 000274513600017
issn
  • 0957-5235
number of pages
http://localhost/t...ganizacniJednotka
  • 41110
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 112 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software