About: Is it possible to measure diameters of metal nanoparticles using BSE imaging in FESEM?     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • The possibilities of using a field emission scanning electron microscope (FESEM) equipped with an Autrata improved yttrium aluminum garnet (YAG) detector of back-scattered electrons (BSE) for a determination of metal nanoparticles sizes were examined in this study. The diameters of Au and Pd nanoparticles with different sizes were resolved based on digitally recorded FESEM micrographs and were compared with diameters obtained with a transmission electron microscope (TEM). In the case of Au nanoparticles, the data obtained from the FESEM exhibited smaller values in comparison with data from the TEM. The Pd nanoparticles diameters measured in the FESEM were comparable with those determined by means of the TEM, however. The influence of various parameters like the sizes of nanoparticles, their composition, use of accelerating voltage and other working conditions in the FESEM on the measurement results are discussed.
  • The possibilities of using a field emission scanning electron microscope (FESEM) equipped with an Autrata improved yttrium aluminum garnet (YAG) detector of back-scattered electrons (BSE) for a determination of metal nanoparticles sizes were examined in this study. The diameters of Au and Pd nanoparticles with different sizes were resolved based on digitally recorded FESEM micrographs and were compared with diameters obtained with a transmission electron microscope (TEM). In the case of Au nanoparticles, the data obtained from the FESEM exhibited smaller values in comparison with data from the TEM. The Pd nanoparticles diameters measured in the FESEM were comparable with those determined by means of the TEM, however. The influence of various parameters like the sizes of nanoparticles, their composition, use of accelerating voltage and other working conditions in the FESEM on the measurement results are discussed. (en)
Title
  • Is it possible to measure diameters of metal nanoparticles using BSE imaging in FESEM?
  • Is it possible to measure diameters of metal nanoparticles using BSE imaging in FESEM? (en)
skos:prefLabel
  • Is it possible to measure diameters of metal nanoparticles using BSE imaging in FESEM?
  • Is it possible to measure diameters of metal nanoparticles using BSE imaging in FESEM? (en)
skos:notation
  • RIV/60077344:_____/13:00397203!RIV14-AV0-60077344
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • I, P(GAP205/10/0348), P(KAN200520704), V
http://linked.open...iv/cisloPeriodika
  • JAN 2013
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 81264
http://linked.open...ai/riv/idVysledku
  • RIV/60077344:_____/13:00397203
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Au nanoparticles; Autrata YAG detector of BSE signal; FESEM; Pd nanoparticles; Size measurement (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • GB - Spojené království Velké Británie a Severního Irska
http://linked.open...ontrolniKodProRIV
  • [1634AD9B6558]
http://linked.open...i/riv/nazevZdroje
  • Micron
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 44
http://linked.open...iv/tvurceVysledku
  • Langhans, Jan
  • Nebesářová, Jana
  • Vancová, Marie
  • Šlouf, Miroslav
  • Pavlova, Ewa
http://linked.open...ain/vavai/riv/wos
  • 000312925300015
issn
  • 0968-4328
number of pages
http://bibframe.org/vocab/doi
  • 10.1016/j.micron.2012.06.002
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 49 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software