About: Effect of the geometry of a working electrode on the behavior of a planar amperometric NO2 sensor based on solid polymer electrolyte     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
rdfs:seeAlso
Description
  • An amperometric NO2 sensor with a new type of solid polymer electrolyte (SPE) and a glassy carbon working electrode is presented. The electrolyte is based on 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide [C2mim][NTf2] ionic liquid immobilized in poly(vinylidene fluoride) matrix [PVDF]. The analyte, gaseous nitrogen dioxide, was detected by reduction at -500 mV vs. a platinum pseudoreference electrode. The sensor exhibited a linear behavior in the whole tested range, i.e., 0 - 10 ppm, and its sensitivity was 0.66x10-6 A/ppm. The rise/recovery times were of the order of tens of seconds. In addition, the influence of the geometry (area and thickness) of the carbon working electrode on sensor response during short-term and long-term exposure to nitrogen dioxide was investigated. The area of the working electrode strongly influenced the stability and noise of the sensor: the smaller the electrode area, the better the stability of the sensor and the lower the noise level. The response times were influenced by the thickness of the carbon working electrode: the thicker the electrode, the longer the response time. It was also demonstrated that glassy carbon is a good candidate for the preparation of the working electrode. The use of a platinum pseudoreference electrode simplifies sensor fabrication and does not have any negative effect on sensor stability.
  • An amperometric NO2 sensor with a new type of solid polymer electrolyte (SPE) and a glassy carbon working electrode is presented. The electrolyte is based on 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide [C2mim][NTf2] ionic liquid immobilized in poly(vinylidene fluoride) matrix [PVDF]. The analyte, gaseous nitrogen dioxide, was detected by reduction at -500 mV vs. a platinum pseudoreference electrode. The sensor exhibited a linear behavior in the whole tested range, i.e., 0 - 10 ppm, and its sensitivity was 0.66x10-6 A/ppm. The rise/recovery times were of the order of tens of seconds. In addition, the influence of the geometry (area and thickness) of the carbon working electrode on sensor response during short-term and long-term exposure to nitrogen dioxide was investigated. The area of the working electrode strongly influenced the stability and noise of the sensor: the smaller the electrode area, the better the stability of the sensor and the lower the noise level. The response times were influenced by the thickness of the carbon working electrode: the thicker the electrode, the longer the response time. It was also demonstrated that glassy carbon is a good candidate for the preparation of the working electrode. The use of a platinum pseudoreference electrode simplifies sensor fabrication and does not have any negative effect on sensor stability. (en)
Title
  • Effect of the geometry of a working electrode on the behavior of a planar amperometric NO2 sensor based on solid polymer electrolyte
  • Effect of the geometry of a working electrode on the behavior of a planar amperometric NO2 sensor based on solid polymer electrolyte (en)
skos:prefLabel
  • Effect of the geometry of a working electrode on the behavior of a planar amperometric NO2 sensor based on solid polymer electrolyte
  • Effect of the geometry of a working electrode on the behavior of a planar amperometric NO2 sensor based on solid polymer electrolyte (en)
skos:notation
  • RIV/49777513:23220/13:43918347!RIV15-MSM-23220___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(ED2.1.00/03.0094), P(LF13018)
http://linked.open...iv/cisloPeriodika
  • October 2013
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 71793
http://linked.open...ai/riv/idVysledku
  • RIV/49777513:23220/13:43918347
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • amperometric sensor, ionic liquid, nitrogen dioxide, solid polymer electrolyte (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • NL - Nizozemsko
http://linked.open...ontrolniKodProRIV
  • [2A2A9E6A4EB6]
http://linked.open...i/riv/nazevZdroje
  • SENSORS AND ACTUATORS B-CHEMICAL
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 187
http://linked.open...iv/tvurceVysledku
  • Hamáček, Aleš
  • Nešpůrek, Stanislav
  • Kuberský, Petr
  • Soukup, Radek
  • Vik, Robert
issn
  • 0925-4005
number of pages
http://bibframe.org/vocab/doi
  • 10.1016/j.snb.2013.03.081
http://localhost/t...ganizacniJednotka
  • 23220
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 48 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software