About: Network configuration impact on during-fault voltage in distribution system     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • The changes in the supply network configuration can significantly influence the voltage at individual sites during fault events. The paper deals with an impact of the network configuration on the voltage dip magnitude, especially with the impact of a network operated in a radial way, a network with loop lines or parallel lines, and the impact of a spot network or a on-site (local) generator. Equations and graphs concerning with the above issues are derived. Their validation is made on the case of a real 110 kV network, partially meshed.
  • The changes in the supply network configuration can significantly influence the voltage at individual sites during fault events. The paper deals with an impact of the network configuration on the voltage dip magnitude, especially with the impact of a network operated in a radial way, a network with loop lines or parallel lines, and the impact of a spot network or a on-site (local) generator. Equations and graphs concerning with the above issues are derived. Their validation is made on the case of a real 110 kV network, partially meshed. (en)
Title
  • Network configuration impact on during-fault voltage in distribution system
  • Network configuration impact on during-fault voltage in distribution system (en)
skos:prefLabel
  • Network configuration impact on during-fault voltage in distribution system
  • Network configuration impact on during-fault voltage in distribution system (en)
skos:notation
  • RIV/49777513:23220/12:43915489!RIV13-MSM-23220___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • I
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 153829
http://linked.open...ai/riv/idVysledku
  • RIV/49777513:23220/12:43915489
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • local generator; power line; network configuration; short-circuit; sag; voltage dip; power quality; distribution system (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [4C18CE31E495]
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Tesařová, Miloslava
http://localhost/t...ganizacniJednotka
  • 23220
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 77 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software