About: Influence of Fault Resistance on the Residual Current at Earth Fault in the Compensated Network     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • This article deals with simulation of electric arc and its influence to the residual current that flows through the earth fault place. The first part describes problems about earth faults and its types. The next, there is introduction to the electric arc and possibilities its simplification for simulation in the program DYNAST. The middle part describes calculations that are necessary to simulations. At the end, there are showed the simulated circuit and results of dependence the residual current on place of earth fault and size of arc resistance. (en)
  • Článek se zabývá modelováním elektrického oblouku a jeho vlivu na zbytkový proud při zemním spojení. První část se zabývá zemním spojením a jeho druhy. Dále je uvedena problematika elektrického oblouku a jeho modelování v programu DYNAST. Na konci jsou uvedeny důležité výpočty pro simulaci, modelovaný obvod a závislost zbytkového proudu na místě zemního spojení a velikosti odporu poruchy.
  • Článek se zabývá modelováním elektrického oblouku a jeho vlivu na zbytkový proud při zemním spojení. První část se zabývá zemním spojením a jeho druhy. Dále je uvedena problematika elektrického oblouku a jeho modelování v programu DYNAST. Na konci jsou uvedeny důležité výpočty pro simulaci, modelovaný obvod a závislost zbytkového proudu na místě zemního spojení a velikosti odporu poruchy. (cs)
Title
  • Influence of Fault Resistance on the Residual Current at Earth Fault in the Compensated Network (en)
  • Vliv odporu poruchy na zbytkový proud při zemním spojení v kompenzované síti
  • Vliv odporu poruchy na zbytkový proud při zemním spojení v kompenzované síti (cs)
skos:prefLabel
  • Influence of Fault Resistance on the Residual Current at Earth Fault in the Compensated Network (en)
  • Vliv odporu poruchy na zbytkový proud při zemním spojení v kompenzované síti
  • Vliv odporu poruchy na zbytkový proud při zemním spojení v kompenzované síti (cs)
skos:notation
  • RIV/49777513:23220/11:43897036!RIV12-MSM-23220___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • S
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 238984
http://linked.open...ai/riv/idVysledku
  • RIV/49777513:23220/11:43897036
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Earth fault, electric arc, arc resistance, residual current, length of arc, DYNAST (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [DF107CB20AFD]
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Síťař, Vladislav
http://localhost/t...ganizacniJednotka
  • 23220
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 48 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software