About: Testing scripts for automated testing of failure detection and DTC storage by ARS166 ECU     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • This task covers writing and debugging of sets of functions for testing of failure detection and right diagnostic trouble codes (DTC) storage by the ARS166 electronic control unit (ECU) during automated hardware in the loop (HIL) testing of the mentioned ECU by using the PROVEtech:TA test environment. These functions control a failure insertion unit (FIU) of the HIL simulator and are called by the test script module according to a testing algorithm. There is one testing script and also one set of functions for checking one possible hardware failure such as open circuit, short circuit to power supply, short circuit to ground and implausible failure of wires to sensors, actuators and CANbus, and also CANbus communication failures. For ARS166 ECU around 80 sets of functions had to be written.
  • This task covers writing and debugging of sets of functions for testing of failure detection and right diagnostic trouble codes (DTC) storage by the ARS166 electronic control unit (ECU) during automated hardware in the loop (HIL) testing of the mentioned ECU by using the PROVEtech:TA test environment. These functions control a failure insertion unit (FIU) of the HIL simulator and are called by the test script module according to a testing algorithm. There is one testing script and also one set of functions for checking one possible hardware failure such as open circuit, short circuit to power supply, short circuit to ground and implausible failure of wires to sensors, actuators and CANbus, and also CANbus communication failures. For ARS166 ECU around 80 sets of functions had to be written. (en)
Title
  • Testing scripts for automated testing of failure detection and DTC storage by ARS166 ECU
  • Testing scripts for automated testing of failure detection and DTC storage by ARS166 ECU (en)
skos:prefLabel
  • Testing scripts for automated testing of failure detection and DTC storage by ARS166 ECU
  • Testing scripts for automated testing of failure detection and DTC storage by ARS166 ECU (en)
skos:notation
  • RIV/49777513:23220/09:00502956!RIV10-MSM-23220___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • N
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 346026
http://linked.open...ai/riv/idVysledku
  • RIV/49777513:23220/09:00502956
http://linked.open...terniIdentifikace
  • 22110-SW008-2009
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Test script; PROVEtech:TA; DTC; Diagnostic Trouble Codes; HIL testing (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [BE18715C7B54]
http://linked.open.../licencniPoplatek
http://linked.open...okalizaceVysledku
  • Mercedes-Benz Technology Center, Sindelfingen, Germany
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...echnickeParametry
  • Functions can be used in the HIL test automation environment PROVEtech:TA made by MBtech. DTC testing of ARS166 covers around 80 sets of functions. One test takes around 3 minutes to execute.
http://linked.open...iv/tvurceVysledku
  • Kubík, Michal
http://linked.open...avai/riv/vlastnik
http://linked.open...itiJinymSubjektem
http://localhost/t...ganizacniJednotka
  • 23220
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 48 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software