About: Amplitude envelope slopes of oscillometric blood pressure waveforms as defined by amplitude ratios     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • Oscillometric methods for blood pressure determination use oscillometric waveform amplitudes. A typical waveform amplitude envelope exhibits a rise of amplitudes at cuff pressures above mean arterial pressure and decrease of amplitudes below mean pressure. Amplitude envelope slopes are functions of several hemodynamic variables. An amplitude envelope can be divided into three segments: segment S1 is the portion of the slope at cuff pressures above systolic pressure, segment S2 is the portion at cuff pressures between systolic and mean pressure, and segment S3 is the slope between mean and diastolic pressure. The slope S2 should be less steep than slope S1 or slope S3 because of the blood flow under the cuff and into the distal vasculature. To test this hypothesis, ten subjects were tested using a specialized data acquisition system. Commercial brachial (upper arm) cuff was used. Results (mean values): S1=0.125, S2=0.056, S3=0.093. All ten S2 slopes were less steep than the slopes S1. The results with
  • Oscillometric methods for blood pressure determination use oscillometric waveform amplitudes. A typical waveform amplitude envelope exhibits a rise of amplitudes at cuff pressures above mean arterial pressure and decrease of amplitudes below mean pressure. Amplitude envelope slopes are functions of several hemodynamic variables. An amplitude envelope can be divided into three segments: segment S1 is the portion of the slope at cuff pressures above systolic pressure, segment S2 is the portion at cuff pressures between systolic and mean pressure, and segment S3 is the slope between mean and diastolic pressure. The slope S2 should be less steep than slope S1 or slope S3 because of the blood flow under the cuff and into the distal vasculature. To test this hypothesis, ten subjects were tested using a specialized data acquisition system. Commercial brachial (upper arm) cuff was used. Results (mean values): S1=0.125, S2=0.056, S3=0.093. All ten S2 slopes were less steep than the slopes S1. The results with (en)
Title
  • Amplitude envelope slopes of oscillometric blood pressure waveforms as defined by amplitude ratios
  • Amplitude envelope slopes of oscillometric blood pressure waveforms as defined by amplitude ratios (en)
skos:prefLabel
  • Amplitude envelope slopes of oscillometric blood pressure waveforms as defined by amplitude ratios
  • Amplitude envelope slopes of oscillometric blood pressure waveforms as defined by amplitude ratios (en)
skos:notation
  • RIV/49777513:23220/09:00502251!RIV10-MPO-23220___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(FT-TA3/058)
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 302661
http://linked.open...ai/riv/idVysledku
  • RIV/49777513:23220/09:00502251
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Bioimpedance; blood pressure; hemodynamic; microcontroller; oscillometric waveforms; sensor (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [B0C5F48F03DC]
http://linked.open...v/mistoKonaniAkce
  • Plzeň
http://linked.open...i/riv/mistoVydani
  • Pilsen
http://linked.open...i/riv/nazevZdroje
  • 2009 Applied Electronics
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Jílek, Jiří
  • Štork, Milan
http://linked.open...vavai/riv/typAkce
http://linked.open...ain/vavai/riv/wos
  • 000273977300029
http://linked.open.../riv/zahajeniAkce
number of pages
http://purl.org/ne...btex#hasPublisher
  • Západočeská univerzita v Plzni
https://schema.org/isbn
  • 978-80-7043-781-0
http://localhost/t...ganizacniJednotka
  • 23220
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software