Attributes | Values |
---|
rdf:type
| |
Description
| - The Quantitative seismocardiography (Q-SCG) opens a new field of cardiovascular dynamics examination. Using this absolutely non-invasive method, a new field of monitoring heart rate variability was opened up. Systolic forces as well as heart rate variability in relation to changes in external stimuli are registered. Q-SCG probably offers a more complex view of both isotropic and chronotropic heart functions. It will be suitable for: examining operators exposed to stress; for assessing the effect of work, fatigue and mental stress; for monitoring persons as part of disease prevention; for determining a person?s ability to carry out their duties both on the ground and in the air. An electronic system for acquisition of data for noninvasive Q-SCG and signal processing is also presented. The measuring system is based on analog filter, analog/digital converter, microcontroller and personal computer. A special digital smoothing polynomial filter is used for signal processing. The example of real measured a
- The Quantitative seismocardiography (Q-SCG) opens a new field of cardiovascular dynamics examination. Using this absolutely non-invasive method, a new field of monitoring heart rate variability was opened up. Systolic forces as well as heart rate variability in relation to changes in external stimuli are registered. Q-SCG probably offers a more complex view of both isotropic and chronotropic heart functions. It will be suitable for: examining operators exposed to stress; for assessing the effect of work, fatigue and mental stress; for monitoring persons as part of disease prevention; for determining a person?s ability to carry out their duties both on the ground and in the air. An electronic system for acquisition of data for noninvasive Q-SCG and signal processing is also presented. The measuring system is based on analog filter, analog/digital converter, microcontroller and personal computer. A special digital smoothing polynomial filter is used for signal processing. The example of real measured a (en)
|
Title
| - Electronic Device for Seismocardiography Noninvasive Examination and Signal Evaluation
- Electronic Device for Seismocardiography Noninvasive Examination and Signal Evaluation (en)
|
skos:prefLabel
| - Electronic Device for Seismocardiography Noninvasive Examination and Signal Evaluation
- Electronic Device for Seismocardiography Noninvasive Examination and Signal Evaluation (en)
|
skos:notation
| - RIV/49777513:23220/09:00502013!RIV10-GA0-23220___
|
http://linked.open...avai/riv/aktivita
| |
http://linked.open...avai/riv/aktivity
| |
http://linked.open...vai/riv/dodaniDat
| |
http://linked.open...aciTvurceVysledku
| |
http://linked.open.../riv/druhVysledku
| |
http://linked.open...iv/duvernostUdaju
| |
http://linked.open...titaPredkladatele
| |
http://linked.open...dnocenehoVysledku
| |
http://linked.open...ai/riv/idVysledku
| - RIV/49777513:23220/09:00502013
|
http://linked.open...riv/jazykVysledku
| |
http://linked.open.../riv/klicovaSlova
| - Quantitative seismocardiography; heart rate; systolic force; direct digital synthesis; analog/digital converter; Savitzki-Golay filter. (en)
|
http://linked.open.../riv/klicoveSlovo
| |
http://linked.open...ontrolniKodProRIV
| |
http://linked.open...v/mistoKonaniAkce
| |
http://linked.open...i/riv/mistoVydani
| |
http://linked.open...i/riv/nazevZdroje
| |
http://linked.open...in/vavai/riv/obor
| |
http://linked.open...ichTvurcuVysledku
| |
http://linked.open...cetTvurcuVysledku
| |
http://linked.open...vavai/riv/projekt
| |
http://linked.open...UplatneniVysledku
| |
http://linked.open...iv/tvurceVysledku
| - Trefný, Martin
- Štork, Milan
- Trefný, Zdeněk
|
http://linked.open...vavai/riv/typAkce
| |
http://linked.open...ain/vavai/riv/wos
| |
http://linked.open.../riv/zahajeniAkce
| |
number of pages
| |
http://purl.org/ne...btex#hasPublisher
| |
https://schema.org/isbn
| |
http://localhost/t...ganizacniJednotka
| |