About: Prediction of voltage dips in an electric power system     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • Voltage dips (sags), mainly caused by remote short circuits, are generally considered the serious power quality problem. Their effect on an operation of sensitive equipment is the same like the effect of short supply interruptions. The knowledge about occurrence of a voltage dips in a network as a function of their magnitude and duration can be obtained through the use of power quality monitors or by means of prediction methods. This paper compares advantages and disadvantages of the voltage dips monitoring and the prediction methods, and limitations of their practical using for the prediction of the number of voltage dips in the power system. The principles of two prediction methods (the method of fault positions and the method of critical distances) are mentioned. The method of fault positions is applied to the real 110 kV grid. The accuracy of the prediction method is evaluated on the basis of the comparison with the outcome of the voltage dip monitoring.
  • Voltage dips (sags), mainly caused by remote short circuits, are generally considered the serious power quality problem. Their effect on an operation of sensitive equipment is the same like the effect of short supply interruptions. The knowledge about occurrence of a voltage dips in a network as a function of their magnitude and duration can be obtained through the use of power quality monitors or by means of prediction methods. This paper compares advantages and disadvantages of the voltage dips monitoring and the prediction methods, and limitations of their practical using for the prediction of the number of voltage dips in the power system. The principles of two prediction methods (the method of fault positions and the method of critical distances) are mentioned. The method of fault positions is applied to the real 110 kV grid. The accuracy of the prediction method is evaluated on the basis of the comparison with the outcome of the voltage dip monitoring. (en)
Title
  • Prediction of voltage dips in an electric power system
  • Prediction of voltage dips in an electric power system (en)
skos:prefLabel
  • Prediction of voltage dips in an electric power system
  • Prediction of voltage dips in an electric power system (en)
skos:notation
  • RIV/49777513:23220/01:00064634!RIV/2002/MSM/232202/N
http://linked.open.../vavai/riv/strany
  • S. 232-236
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • Z(MSM 232200008)
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 692387
http://linked.open...ai/riv/idVysledku
  • RIV/49777513:23220/01:00064634
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Dip; power quality; failure rate; electric grid; short circuit analysis; (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [FC259FC27EA7]
http://linked.open...v/mistoKonaniAkce
  • Neuveden
http://linked.open...i/riv/mistoVydani
  • Neuveden
http://linked.open...i/riv/nazevZdroje
  • Prediction of voltage dips in an electric power system
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...ocetUcastnikuAkce
http://linked.open...nichUcastnikuAkce
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Tesařová, Miloslava
http://linked.open...vavai/riv/typAkce
http://linked.open.../riv/zahajeniAkce
http://linked.open...n/vavai/riv/zamer
number of pages
http://purl.org/ne...btex#hasPublisher
  • Neuveden
http://localhost/t...ganizacniJednotka
  • 23220
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 77 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software