  • This article describes the measurement of the influence of the wall temperature on flow from the floor convector. The measurement is realized in an open space laboratory. The velocity field at the convector inlet and outlet. is visualized using PIV technique. Two temperatures 19.8 degrees C and 12.5 degrees C are set at the wall to evaluate the influence of the wall cooling.
  • This article describes the measurement of the influence of the wall temperature on flow from the floor convector. The measurement is realized in an open space laboratory. The velocity field at the convector inlet and outlet. is visualized using PIV technique. Two temperatures 19.8 degrees C and 12.5 degrees C are set at the wall to evaluate the influence of the wall cooling. (en)
Title
  • The influence of the wall temperature on the flow from the floor convector
  • The influence of the wall temperature on the flow from the floor convector (en)
skos:prefLabel
  • The influence of the wall temperature on the flow from the floor convector
  • The influence of the wall temperature on the flow from the floor convector (en)
skos:notation
  • RIV/46747885:24620/12:#0000398!RIV14-TA0-24620___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(ED0005/01/01), P(EE2.3.30.0024), P(TA01020231)
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 141654
http://linked.open...ai/riv/idVysledku
  • RIV/46747885:24620/12:#0000398
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • floor convector, temperature field, PIV measurement (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [FDC0062BFD48]
http://linked.open...v/mistoKonaniAkce
  • Hradec Králové
http://linked.open...i/riv/mistoVydani
  • CEDEX A, FRANCE
http://linked.open...i/riv/nazevZdroje
  • EPJ Web of Conferences, Volume 45, 2013, EFM12 – Experimental Fluid Mechanics 2012
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Dančová, Petra
  • Fraňa, Karel
  • Kotek, Michal
  • Muller, Miloš
http://linked.open...vavai/riv/typAkce
http://linked.open...ain/vavai/riv/wos
  • 000319932200130
http://linked.open.../riv/zahajeniAkce
issn
  • 2100-014X
number of pages
http://bibframe.org/vocab/doi
  • 10.1051/epjconf/20134501130
http://purl.org/ne...btex#hasPublisher
  • E D P SCIENCES
https://schema.org/isbn
  • 978-80-7372-912-7
http://localhost/t...ganizacniJednotka
  • 24620
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 110 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software