About: Colour Differences for a Farnsworth-Muunsell 100-Hue Test Illuminated by a D65 source     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • From experimental measurements of the 85 samples in a completely new issue of the Farnsworth-Munsell 100-Hue test (D65 source, CIE 1931 colorimetric observer), the next main conclusions were achieved: 1) The 85 samples had almost constant lightness, but high chroma variations (coefficients of variation of L*=3.2% and Cab*=23.7%). 2) On the average, continuous samples showed CIEDE2000 lightness-, chroma- and hue-differences of 26.1%, 12.2% and 61.7%, respectively. 3) Colour differences between contiguous samples had high coefficients of variation of 33.9% and 33.5% for the CIEDE2000 and CAMO2-SCD colour-difference formulas respectively. 4) The next anomalous colour-difference pairs were detected: DE(27, 29)< DE(27, 28); DE(35 , 33) < DE(35, 34); DE(47, 49) < DE(47,48); and DE(49 47)< DE(49,48), where DE designates both the CIEDE2000 and CAMO2-SCD colour-difference formulas. 5) Although the reference illuminant for this test was C, the use of illuminant D65 or an appropriate simulator can be also admitted, bearing in mind that average colour differences between contiguous samples change less than 0.1 CIELAB units. In summary, although current results must be tested from other issues of the FM-100 test, probably it will be convenient to revise the set of samples provided by the FM-100 test, looking for an improved uniformity in modem colour spaces.
  • From experimental measurements of the 85 samples in a completely new issue of the Farnsworth-Munsell 100-Hue test (D65 source, CIE 1931 colorimetric observer), the next main conclusions were achieved: 1) The 85 samples had almost constant lightness, but high chroma variations (coefficients of variation of L*=3.2% and Cab*=23.7%). 2) On the average, continuous samples showed CIEDE2000 lightness-, chroma- and hue-differences of 26.1%, 12.2% and 61.7%, respectively. 3) Colour differences between contiguous samples had high coefficients of variation of 33.9% and 33.5% for the CIEDE2000 and CAMO2-SCD colour-difference formulas respectively. 4) The next anomalous colour-difference pairs were detected: DE(27, 29)< DE(27, 28); DE(35 , 33) < DE(35, 34); DE(47, 49) < DE(47,48); and DE(49 47)< DE(49,48), where DE designates both the CIEDE2000 and CAMO2-SCD colour-difference formulas. 5) Although the reference illuminant for this test was C, the use of illuminant D65 or an appropriate simulator can be also admitted, bearing in mind that average colour differences between contiguous samples change less than 0.1 CIELAB units. In summary, although current results must be tested from other issues of the FM-100 test, probably it will be convenient to revise the set of samples provided by the FM-100 test, looking for an improved uniformity in modem colour spaces. (en)
Title
  • Colour Differences for a Farnsworth-Muunsell 100-Hue Test Illuminated by a D65 source
  • Colour Differences for a Farnsworth-Muunsell 100-Hue Test Illuminated by a D65 source (en)
skos:prefLabel
  • Colour Differences for a Farnsworth-Muunsell 100-Hue Test Illuminated by a D65 source
  • Colour Differences for a Farnsworth-Muunsell 100-Hue Test Illuminated by a D65 source (en)
skos:notation
  • RIV/46747885:24410/11:#0001000!RIV12-MSM-24410___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(1M0553)
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 190850
http://linked.open...ai/riv/idVysledku
  • RIV/46747885:24410/11:#0001000
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Farnsworth-Munsell 100-Hue Test; Colorimetry; CIE; Color difference (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [7D8361C6B63B]
http://linked.open...v/mistoKonaniAkce
  • Zurich
http://linked.open...i/riv/mistoVydani
  • Zurich, Switzerland
http://linked.open...i/riv/nazevZdroje
  • AIC 2011 Midterm Meeting - Interaction of Colours and Light in the Arts and Science - Proceeding
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • García-Romera, M.
  • Gómez-Robledo, L.
  • Melgosa, M.
  • Okajima, K.
  • Vik, Michal
  • Viková, Martina
http://linked.open...vavai/riv/typAkce
http://linked.open.../riv/zahajeniAkce
number of pages
http://purl.org/ne...btex#hasPublisher
  • pro/colore, Swiss
https://schema.org/isbn
  • 978-3-033-02929-3
http://localhost/t...ganizacniJednotka
  • 24410
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 48 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software