About: Identification of the mechanical properties of the cervical implant material     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • The aim of this paper is the identification of mechanical parameters of cervical implant material and the mechanical structure. This mechanical structure was designed for measuring the biomechanical interaction between the implant and the surrounding bone. The main idea of this device is based on the dynamic response of connected structure. It is important to know how and how much the parameters of structure response depend on the boundary conditions which are represented by the surrounding bone or another support. Boundary conditions will be represented by two cases. In first case will be described linear model of boundary condition and in second case will be described non – linear model. It is necessary to know how the linearities or non-linearities influence the response of the structure and where the non-linearities can occur. Will be described the experimental device and its mathematical model. The cervical implant will be represented as a connection between the surrounding bone and the mechanical structure. By the comparison the numerical simulation and experimental data will be identified the parameters of simplified mathematical model. Experimental device will be put to the dynamic excitation and the response of system will be measured.
  • The aim of this paper is the identification of mechanical parameters of cervical implant material and the mechanical structure. This mechanical structure was designed for measuring the biomechanical interaction between the implant and the surrounding bone. The main idea of this device is based on the dynamic response of connected structure. It is important to know how and how much the parameters of structure response depend on the boundary conditions which are represented by the surrounding bone or another support. Boundary conditions will be represented by two cases. In first case will be described linear model of boundary condition and in second case will be described non – linear model. It is necessary to know how the linearities or non-linearities influence the response of the structure and where the non-linearities can occur. Will be described the experimental device and its mathematical model. The cervical implant will be represented as a connection between the surrounding bone and the mechanical structure. By the comparison the numerical simulation and experimental data will be identified the parameters of simplified mathematical model. Experimental device will be put to the dynamic excitation and the response of system will be measured. (en)
Title
  • Identification of the mechanical properties of the cervical implant material
  • Identification of the mechanical properties of the cervical implant material (en)
skos:prefLabel
  • Identification of the mechanical properties of the cervical implant material
  • Identification of the mechanical properties of the cervical implant material (en)
skos:notation
  • RIV/46747885:24210/12:#0002736!RIV13-MSM-24210___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • S
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 140338
http://linked.open...ai/riv/idVysledku
  • RIV/46747885:24210/12:#0002736
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Finite element analysis; Experimental analysis; Implant stability; Response function (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [2C7632D03DB2]
http://linked.open...v/mistoKonaniAkce
  • Tábor
http://linked.open...i/riv/mistoVydani
  • Praha
http://linked.open...i/riv/nazevZdroje
  • PROCEEDINGS OF THE 50TH ANNUAL CONFERENCE ON EXPERIMENTAL STRESS ANALYSIS
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Škoda, Jan
  • Henyš, Petr
http://linked.open...vavai/riv/typAkce
http://linked.open.../riv/zahajeniAkce
number of pages
http://purl.org/ne...btex#hasPublisher
  • CZECH TECHNICAL UNIV PRAGUE
https://schema.org/isbn
  • 978-80-01-05060-6
http://localhost/t...ganizacniJednotka
  • 24210
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 107 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software