| - Three types of NPP cables (with jacket/insulation combinations PVC/PVC, PVC/PE, XPE/XPE) were irradiated at room temperature using 60Co gamma ray source at average dose rates of 7, 30 and 100 Gy/h with the doses up to 590 kGy. The irradiated samples have been tested for their mechanical properties, thermo-oxidative stability (using differential scanning calorimetry, DSC), and density.
- Three types of NPP cables (with jacket/insulation combinations PVC/PVC, PVC/PE, XPE/XPE) were irradiated at room temperature using 60Co gamma ray source at average dose rates of 7, 30 and 100 Gy/h with the doses up to 590 kGy. The irradiated samples have been tested for their mechanical properties, thermo-oxidative stability (using differential scanning calorimetry, DSC), and density. (en)
- U tří kabelů, používaných v jaderných elektrárnách, byl sledován vliv dávkového příkonu na degradaci polymerních kabelových izolací. K experimentům byly použity kabely s pláštěm a izolací žíly na bázi PVC/PVC, PVC/PE a XPE/XPE. Vzorky byly ozářeny gama zářením ze zdroje 60Co při průměrném dávkovém příkonu 7, 30 a 100 Gy/h, maximální absorbovaná dávka byla 590 kGy. Degradace polymerních izolací byla sledována pomocí měření mechanických vlastností, termooxidační stability a hustoty. (cs)
|
Title
| - Vliv dávkového příkonu při ozařování polymerních kabelových materiálů (cs)
- Dose rate effects in radiation on polymer-based cable materials
- Dose rate effects in radiation on polymer-based cable materials (en)
|
skos:prefLabel
| - Vliv dávkového příkonu při ozařování polymerních kabelových materiálů (cs)
- Dose rate effects in radiation on polymer-based cable materials
- Dose rate effects in radiation on polymer-based cable materials (en)
|
skos:notation
| - RIV/46356088:_____/03:#0000474!RIV08-MSM-46356088
|
http://linked.open.../vavai/riv/strany
| |
http://linked.open...avai/riv/aktivita
| |
http://linked.open...avai/riv/aktivity
| |
http://linked.open...iv/cisloPeriodika
| |
http://linked.open...vai/riv/dodaniDat
| |
http://linked.open...aciTvurceVysledku
| |
http://linked.open.../riv/druhVysledku
| |
http://linked.open...iv/duvernostUdaju
| |
http://linked.open...titaPredkladatele
| |
http://linked.open...dnocenehoVysledku
| |
http://linked.open...ai/riv/idVysledku
| - RIV/46356088:_____/03:#0000474
|
http://linked.open...riv/jazykVysledku
| |
http://linked.open.../riv/klicovaSlova
| - dose rate; nuclear power plant; polymer; cable (en)
|
http://linked.open.../riv/klicoveSlovo
| |
http://linked.open...odStatuVydavatele
| |
http://linked.open...ontrolniKodProRIV
| |
http://linked.open...i/riv/nazevZdroje
| - Nuclear Instruments and Methods in Physics Research B
|
http://linked.open...in/vavai/riv/obor
| |
http://linked.open...ichTvurcuVysledku
| |
http://linked.open...cetTvurcuVysledku
| |
http://linked.open...UplatneniVysledku
| |
http://linked.open...v/svazekPeriodika
| |
http://linked.open...iv/tvurceVysledku
| - Plaček, Vít
- Bartoníček, Bohumil
- Hnát, Vladimír
|
issn
| |
number of pages
| |