About: The Comparison of ICP-OES, F-AAS and gravimetric analysis for the determination of the low concentration of SIO2 in matrix of calcite     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • Laboratory of analytical chemistry and ecotoxicology accredited by ČIA (Czech accreditation institute) is dealt not only with improvement of existing methods and processes but also on development of new method. Presently, the inductively coupled plasma-optical emission spectrometry (ICP-OES) and flame atomic absorption spectrometry (F-AAS) were tested as methods for the determination of the low concentration of silicium dioxide in several kinds of matrix. ISBN 978-80-254-4447-4 (en)
  • Akreditovaná zkušební laboratoř analytické chemie a ekotoxikologie Výzkumného ústavu stavebních hmot se zaměřuje nejen na zdokonalování stávajících zkušebních postupů a metod, ale také na vývoj metod nových. Nejnověji se v laboratoři analytické chemie testují nové metody stanovení nízkých obsahů SiO2 na ICP-OES a AAS ve vybraných matricích. ISBN 978-80-254-4447-4
  • Akreditovaná zkušební laboratoř analytické chemie a ekotoxikologie Výzkumného ústavu stavebních hmot se zaměřuje nejen na zdokonalování stávajících zkušebních postupů a metod, ale také na vývoj metod nových. Nejnověji se v laboratoři analytické chemie testují nové metody stanovení nízkých obsahů SiO2 na ICP-OES a AAS ve vybraných matricích. ISBN 978-80-254-4447-4 (cs)
Title
  • The Comparison of ICP-OES, F-AAS and gravimetric analysis for the determination of the low concentration of SIO2 in matrix of calcite (en)
  • Srovnání metod (ICP-OES, F-AAS a gravimetrie) pro stanovení nízkých koncentrací SiO2 ve výpencové matrice
  • Srovnání metod (ICP-OES, F-AAS a gravimetrie) pro stanovení nízkých koncentrací SiO2 ve výpencové matrice (cs)
skos:prefLabel
  • The Comparison of ICP-OES, F-AAS and gravimetric analysis for the determination of the low concentration of SIO2 in matrix of calcite (en)
  • Srovnání metod (ICP-OES, F-AAS a gravimetrie) pro stanovení nízkých koncentrací SiO2 ve výpencové matrice
  • Srovnání metod (ICP-OES, F-AAS a gravimetrie) pro stanovení nízkých koncentrací SiO2 ve výpencové matrice (cs)
skos:notation
  • RIV/26232511:_____/10:VEZPO118!RIV11-MSM-26232511
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • Z(MSM2623251101)
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 289478
http://linked.open...ai/riv/idVysledku
  • RIV/26232511:_____/10:VEZPO118
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • ICP-OES; F-AAS (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [95AB11C84A72]
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Urbánková, Kristýna
  • Pavlitová Letková, Zuzana
http://linked.open...n/vavai/riv/zamer
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 34 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software