About: The possibility of using the specific RIA method for the area-under-time-concentration curve sparse sampling calculation of cyclosporin A despite a large post-dose overestimation     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • OBJECTIVE: To find limited sampling strategies (LSS) for prediction of the real AUC using the RIA analytical method. METHOD: Blood samples of 40 male renal transplant patients taken pre-dose and after 0.5, 1, 1.5, 2, 3, 5, 8, and 12 h in the steady-state were analyzed with HPLC and the specific RIA method. I. Eight equations for AUC0-12 and one for AUC0-8 obtained from the literature, that produced the mean percentage prediction error (%PE) < 15% and absolute %PE < 30% in 95% of predictions, were analyzed for possibility to predict the real AUC of CsA. II. Multiple regression analysis (MRA) was provided for the AUC equation proposal. Patients were divided into two groups according to the AUC0-12. Group I was used for LSS : s proposals while Group II for validation. The bias and precision were expressed as %PE, r2 and RMSE. The relationship of %PE interassay and with LSS:s was expressed as Pearson correlation r. GraphPad InStatt Software was used for MRA and Pearson r calculation. RESULTS: None of the equations described in the literature predicts AUC of CsA proprietarily. Seven equations for AUC0-12 and five for AUC0-8 were proposed with MRA for prediction of real AUC from RIA values. CONCLUSIONS: LSS:s can moderate the interassay %PE in AUC of CsA. New patients should be tested with both RIA and HPLC for the level of overestimation. The conversion factors should be calculated for patients with an overestimation higher than 90%. Our equation 251.09 + 0.5195 C1h + 4.926 C3h or 196.13 + 4.526  C0h + 2.089 C1.5h for AUC0-12, and 171.80 + 0.4759 C1h + 4.132 C3h for AUC0-8 may be used in patients with medium or low RIA and HPLC differences. Repeated analysis with HPLC is thus suggested in cases with AUC:s results close to the lower or upper margin of the therapeutic window.
  • OBJECTIVE: To find limited sampling strategies (LSS) for prediction of the real AUC using the RIA analytical method. METHOD: Blood samples of 40 male renal transplant patients taken pre-dose and after 0.5, 1, 1.5, 2, 3, 5, 8, and 12 h in the steady-state were analyzed with HPLC and the specific RIA method. I. Eight equations for AUC0-12 and one for AUC0-8 obtained from the literature, that produced the mean percentage prediction error (%PE) < 15% and absolute %PE < 30% in 95% of predictions, were analyzed for possibility to predict the real AUC of CsA. II. Multiple regression analysis (MRA) was provided for the AUC equation proposal. Patients were divided into two groups according to the AUC0-12. Group I was used for LSS : s proposals while Group II for validation. The bias and precision were expressed as %PE, r2 and RMSE. The relationship of %PE interassay and with LSS:s was expressed as Pearson correlation r. GraphPad InStatt Software was used for MRA and Pearson r calculation. RESULTS: None of the equations described in the literature predicts AUC of CsA proprietarily. Seven equations for AUC0-12 and five for AUC0-8 were proposed with MRA for prediction of real AUC from RIA values. CONCLUSIONS: LSS:s can moderate the interassay %PE in AUC of CsA. New patients should be tested with both RIA and HPLC for the level of overestimation. The conversion factors should be calculated for patients with an overestimation higher than 90%. Our equation 251.09 + 0.5195 C1h + 4.926 C3h or 196.13 + 4.526  C0h + 2.089 C1.5h for AUC0-12, and 171.80 + 0.4759 C1h + 4.132 C3h for AUC0-8 may be used in patients with medium or low RIA and HPLC differences. Repeated analysis with HPLC is thus suggested in cases with AUC:s results close to the lower or upper margin of the therapeutic window. (en)
Title
  • The possibility of using the specific RIA method for the area-under-time-concentration curve sparse sampling calculation of cyclosporin A despite a large post-dose overestimation
  • The possibility of using the specific RIA method for the area-under-time-concentration curve sparse sampling calculation of cyclosporin A despite a large post-dose overestimation (en)
skos:prefLabel
  • The possibility of using the specific RIA method for the area-under-time-concentration curve sparse sampling calculation of cyclosporin A despite a large post-dose overestimation
  • The possibility of using the specific RIA method for the area-under-time-concentration curve sparse sampling calculation of cyclosporin A despite a large post-dose overestimation (en)
skos:notation
  • RIV/00843989:_____/11:00101974!RIV13-MZ0-00843989
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(1A8655), S, V
http://linked.open...iv/cisloPeriodika
  • 1
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 221803
http://linked.open...ai/riv/idVysledku
  • RIV/00843989:_____/11:00101974
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • cyclosporin; sparse sampling; validation; multiple linear regression; AUC (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • DE - Spolková republika Německo
http://linked.open...ontrolniKodProRIV
  • [4A2940A6038B]
http://linked.open...i/riv/nazevZdroje
  • International journal of clinical pharmacology and therapeutics
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 49
http://linked.open...iv/tvurceVysledku
  • Brozmanová, Hana
  • Grundmann, Milan
  • Kořístková, Blanka
  • Peřinová, Ilona
  • Šafarčík, Kristian
http://linked.open...ain/vavai/riv/wos
  • 000287285800005
issn
  • 0946-1965
number of pages
http://bibframe.org/vocab/doi
  • 10.5414/CPP49030
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software