About: Automated Voltammetric Determination of Lead(II) Ions Using Sensor Array     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • The aim of this work was to design and to construct new automated system for electrochemical determination of metal ions. For this purpose, we connected three commercially available instruments with sensor field and control box. Suggested field consists from 96 electrode systems, in which working electrode was made from carbon. The detection limit (3 S/N) was estimated as 1 ug/ml.
  • The aim of this work was to design and to construct new automated system for electrochemical determination of metal ions. For this purpose, we connected three commercially available instruments with sensor field and control box. Suggested field consists from 96 electrode systems, in which working electrode was made from carbon. The detection limit (3 S/N) was estimated as 1 ug/ml. (en)
Title
  • Automated Voltammetric Determination of Lead(II) Ions Using Sensor Array
  • Automated Voltammetric Determination of Lead(II) Ions Using Sensor Array (en)
skos:prefLabel
  • Automated Voltammetric Determination of Lead(II) Ions Using Sensor Array
  • Automated Voltammetric Determination of Lead(II) Ions Using Sensor Array (en)
skos:notation
  • RIV/00216305:26620/13:PU103766!RIV14-MSM-26620___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(ED1.1.00/02.0068), P(EE2.4.31.0023), Z(MSM6215648902)
http://linked.open...iv/cisloPeriodika
  • 4
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 62581
http://linked.open...ai/riv/idVysledku
  • RIV/00216305:26620/13:PU103766
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Lead, Electrochemical Analysis, Screen Printed Electrode, Differential Pulse Voltammetry, Automated Analysis (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • RS - Srbská republika
http://linked.open...ontrolniKodProRIV
  • [EBC6BC1B4F7F]
http://linked.open...i/riv/nazevZdroje
  • INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 8
http://linked.open...iv/tvurceVysledku
  • Adam, Vojtěch
  • Chomoucká, Jana
  • Drbohlavová, Jana
  • Hubálek, Jaromír
  • Hynek, David
  • Kizek, René
  • Kynický, Jindřich
  • Majzlíková, Petra
  • Prášek, Jan
  • Vrba, Radimír
  • Žák, Jaromír
  • Konečná, Marie
  • Brnický, Martin
http://linked.open...n/vavai/riv/zamer
issn
  • 1452-3981
number of pages
http://localhost/t...ganizacniJednotka
  • 26620
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software