About: Diagnostics of Electrical Discharges in Electrolytes: Influence of Electrode and Diaphragm Configuration     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • This paper deals with electrical discharge ignition in water solutions of selected electrolytes (NaCl, NaBr, and Na3PO4), and it describes particular processes before and after discharge breakdown by DC non-pulsed voltage up to 2 kV. Diaphragm configuration, with possibility to change the electrode distance (from 2 to 8 cm) and with different pin-hole diameters (0.3-0.6 mm), was used in experiments in order to estimate aninfluence of configuration parameters on the breakdown moment. The diaphragm was made of PET with its thickness of 0.25 mm. It was proved that the breakdown appeared at higher applied voltage when the electrode distance was enhanced. The influence of pin-hole diameter was less obvious in the studied range ,but a slight enhancement of breakdown voltage was observed with the increasing pin-hole diameter.
  • This paper deals with electrical discharge ignition in water solutions of selected electrolytes (NaCl, NaBr, and Na3PO4), and it describes particular processes before and after discharge breakdown by DC non-pulsed voltage up to 2 kV. Diaphragm configuration, with possibility to change the electrode distance (from 2 to 8 cm) and with different pin-hole diameters (0.3-0.6 mm), was used in experiments in order to estimate aninfluence of configuration parameters on the breakdown moment. The diaphragm was made of PET with its thickness of 0.25 mm. It was proved that the breakdown appeared at higher applied voltage when the electrode distance was enhanced. The influence of pin-hole diameter was less obvious in the studied range ,but a slight enhancement of breakdown voltage was observed with the increasing pin-hole diameter. (en)
Title
  • Diagnostics of Electrical Discharges in Electrolytes: Influence of Electrode and Diaphragm Configuration
  • Diagnostics of Electrical Discharges in Electrolytes: Influence of Electrode and Diaphragm Configuration (en)
skos:prefLabel
  • Diagnostics of Electrical Discharges in Electrolytes: Influence of Electrode and Diaphragm Configuration
  • Diagnostics of Electrical Discharges in Electrolytes: Influence of Electrode and Diaphragm Configuration (en)
skos:notation
  • RIV/00216305:26310/11:PU90905!RIV11-GA0-26310___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(GP202/07/P371), S
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 194240
http://linked.open...ai/riv/idVysledku
  • RIV/00216305:26310/11:PU90905
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • discharges in water, diaphragm configuration, electrical characteristics, discharge breakdown, bubble formation (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [672D8A167BA2]
http://linked.open...v/mistoKonaniAkce
  • Vrátna
http://linked.open...i/riv/mistoVydani
  • Bratislava
http://linked.open...i/riv/nazevZdroje
  • Book of Contributed Papers: 18th Symposium on Application of Plasma Processes and Workshop on Plasmas as a Planetary Atmospheres Mimics
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Krčma, František
  • Hlavatá, Lucie
  • Kozáková, Zdenka
http://linked.open...vavai/riv/typAkce
http://linked.open.../riv/zahajeniAkce
number of pages
http://purl.org/ne...btex#hasPublisher
  • Neuveden
https://schema.org/isbn
  • 978-80-89186-77-8
http://localhost/t...ganizacniJednotka
  • 26310
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software