  • This article describes the partial discharges (PD) detection and localization system. Localization can be performed on the basis of measured UHF waveforms analysis during activity of the partial discharges. The time-shifts of the waveforms related to transient process occurrence in the signals are the main input parameters for localization methods. In order to estimate the position of the signal source in the 3D space a minimum of four antennas has to be used, since the time of the PD is unknown. Analysis of the PD starts with visual investigation of the signals present inside of the power oil transformer. PD signal level is in comparison to other signals inside the transformer very low. Therefore, signal line contains, except amplifiers, also controlled attenuators to reach required trigger conditions. Detailed investigation of all signals inside transformer is provided in memory mode in which system store defined number of signals for offline diagnosis a localization. Continual and memory mode of th
  • This article describes the partial discharges (PD) detection and localization system. Localization can be performed on the basis of measured UHF waveforms analysis during activity of the partial discharges. The time-shifts of the waveforms related to transient process occurrence in the signals are the main input parameters for localization methods. In order to estimate the position of the signal source in the 3D space a minimum of four antennas has to be used, since the time of the PD is unknown. Analysis of the PD starts with visual investigation of the signals present inside of the power oil transformer. PD signal level is in comparison to other signals inside the transformer very low. Therefore, signal line contains, except amplifiers, also controlled attenuators to reach required trigger conditions. Detailed investigation of all signals inside transformer is provided in memory mode in which system store defined number of signals for offline diagnosis a localization. Continual and memory mode of th (en)
Title
  • Partial discharge detection and localization system
  • Partial discharge detection and localization system (en)
skos:prefLabel
  • Partial discharge detection and localization system
  • Partial discharge detection and localization system (en)
skos:notation
  • RIV/00216305:26220/14:PU110613!RIV15-MSM-26220___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • S
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 35800
http://linked.open...ai/riv/idVysledku
  • RIV/00216305:26220/14:PU110613
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • partial discharge, UHF method, source localization (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [60B123229397]
http://linked.open...v/mistoKonaniAkce
  • Guangzhou
http://linked.open...i/riv/mistoVydani
  • Neuveden
http://linked.open...i/riv/nazevZdroje
  • Progress in Electromagnetics Research Symposium 2014, Guangzhou
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Drexler, Petr
  • Fiala, Pavel
  • Čáp, Martin
http://linked.open...vavai/riv/typAkce
http://linked.open.../riv/zahajeniAkce
number of pages
http://purl.org/ne...btex#hasPublisher
  • Neuveden
https://schema.org/isbn
  • 978-1-934142-28-8
http://localhost/t...ganizacniJednotka
  • 26220
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 48 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software