About: The Evaluation of Overvoltage During Short-Time Additional Earthing of Healthy Phase for Fault Location in MV Networks     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • The paper is focused on the operational experience with an automatic system for additional earthing of the faulty or healthy phase during an earth fault. The system is primarily used for limiting of a fault current in the point of the fault by earthing of the faulty phase during an earth fault. The equipment for additional earthing of faulty phase can also be used for short-time connection of healthy phase to earth fault location. There are fast circuit breakers for additional earthing in the substation and the cycle close-open is shorter then time for tripping of overcurrent protection in the outgoing feeder-bay (100 ms). This method of fault location in MV network could bring additional overvoltage which stresses the insulation of MV networks elements. This paper presents the simulation and experimental verification of this phenomenon and gives the recommendation for choosing the healthy phase for minimizing the negative influence of this location technique.
  • The paper is focused on the operational experience with an automatic system for additional earthing of the faulty or healthy phase during an earth fault. The system is primarily used for limiting of a fault current in the point of the fault by earthing of the faulty phase during an earth fault. The equipment for additional earthing of faulty phase can also be used for short-time connection of healthy phase to earth fault location. There are fast circuit breakers for additional earthing in the substation and the cycle close-open is shorter then time for tripping of overcurrent protection in the outgoing feeder-bay (100 ms). This method of fault location in MV network could bring additional overvoltage which stresses the insulation of MV networks elements. This paper presents the simulation and experimental verification of this phenomenon and gives the recommendation for choosing the healthy phase for minimizing the negative influence of this location technique. (en)
Title
  • The Evaluation of Overvoltage During Short-Time Additional Earthing of Healthy Phase for Fault Location in MV Networks
  • The Evaluation of Overvoltage During Short-Time Additional Earthing of Healthy Phase for Fault Location in MV Networks (en)
skos:prefLabel
  • The Evaluation of Overvoltage During Short-Time Additional Earthing of Healthy Phase for Fault Location in MV Networks
  • The Evaluation of Overvoltage During Short-Time Additional Earthing of Healthy Phase for Fault Location in MV Networks (en)
skos:notation
  • RIV/00216305:26220/14:PU108900!RIV15-MSM-26220___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(EE2.3.30.0005)
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 15407
http://linked.open...ai/riv/idVysledku
  • RIV/00216305:26220/14:PU108900
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • earth fault, fault location, overvoltage, earthing, healthy phase (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [465B51FFD935]
http://linked.open...v/mistoKonaniAkce
  • Copenhagen
http://linked.open...i/riv/mistoVydani
  • Six Hills Way Stevenage Hertfordshire SG1 2AY UK
http://linked.open...i/riv/nazevZdroje
  • The 12th International Conference on Developments in Power System Protection DPSP2014
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Toman, Petr
  • Orságová, Jaroslava
  • Topolánek, David
  • Kopička, Marek
http://linked.open...vavai/riv/typAkce
http://linked.open.../riv/zahajeniAkce
number of pages
http://bibframe.org/vocab/doi
  • 10.1049/cp.2014.0160
http://purl.org/ne...btex#hasPublisher
  • The Institution of Engineering and Technology IET
https://schema.org/isbn
  • 978-1-84919-834-9
http://localhost/t...ganizacniJednotka
  • 26220
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 48 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software