About: Cu2O based electrochemical sensor for direct glucose detection     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
rdfs:seeAlso
Description
  • Two types of working electrodes of electrochemical sensors were fabricated using screen-printing and spray-coating deposition methods and previously synthetized Cu2O micro/nanoparticles and used for direct electrochemical glucose detection. Glucose was successfully electrochemically detected against conventional Ag/AgCl reference electrode and platinum auxiliary electrode at potential of 0.5 V and 0.75 V for spray coated and screen printed electrode, respectively. Better sensitivity was observed using spray-coated electrode. For both electrodes types we obtained linear calibration curve in physiological range of concentrations from 0.5 to 10 mmol/L. Furthermore, the limit of detection lower than 100 umol/L was achieved.
  • Two types of working electrodes of electrochemical sensors were fabricated using screen-printing and spray-coating deposition methods and previously synthetized Cu2O micro/nanoparticles and used for direct electrochemical glucose detection. Glucose was successfully electrochemically detected against conventional Ag/AgCl reference electrode and platinum auxiliary electrode at potential of 0.5 V and 0.75 V for spray coated and screen printed electrode, respectively. Better sensitivity was observed using spray-coated electrode. For both electrodes types we obtained linear calibration curve in physiological range of concentrations from 0.5 to 10 mmol/L. Furthermore, the limit of detection lower than 100 umol/L was achieved. (en)
Title
  • Cu2O based electrochemical sensor for direct glucose detection
  • Cu2O based electrochemical sensor for direct glucose detection (en)
skos:prefLabel
  • Cu2O based electrochemical sensor for direct glucose detection
  • Cu2O based electrochemical sensor for direct glucose detection (en)
skos:notation
  • RIV/00216305:26220/13:PU105912!RIV14-MSM-26220___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(ED2.1.00/03.0072), P(EE2.3.20.0027)
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 67589
http://linked.open...ai/riv/idVysledku
  • RIV/00216305:26220/13:PU105912
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Cu2O, Copper oxide, electrochemical senzor, glucose, electrochemical detection (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [2B45D74F3A25]
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Chomoucká, Jana
  • Drbohlavová, Jana
  • Hubálek, Jaromír
  • Hrdý, Radim
  • Majzlíková, Petra
  • Pekárek, Jan
  • Prášek, Jan
  • Trnková, Libuše
http://localhost/t...ganizacniJednotka
  • 26220
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   