About: The Influence of Additional Earthing of Healthy Phase for Earth Fault Location on Safety of Compensated Networks     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • A connection between a phase conductor and the ground in a compensated MV networks is called an earth fault. Since the fault current in this case does not depend on the point of the fault, but only on the total capacity (size) of a network, earth fault location remains a problem for MV network operators. The MV compensated Networks in Czech Republic are operated as nonsymmetrical, that means as networks with non-transposed lines. Some of them are operated with additional earthing of faulted phase for increasing the safety in the point of the fault. The equipment of additional earthing of faulted phase is also able to connect healthy phase for short time. There are fast circuit breakers for additional earthing in the substation and the cycle close-open is shorter than time for tripping of an overcurrent protection in the outgoing feeder-bay (100ms). The paper deals with analysis of the touch voltages in the point of the fault during fault location and describes the experiment in real distribution netw
  • A connection between a phase conductor and the ground in a compensated MV networks is called an earth fault. Since the fault current in this case does not depend on the point of the fault, but only on the total capacity (size) of a network, earth fault location remains a problem for MV network operators. The MV compensated Networks in Czech Republic are operated as nonsymmetrical, that means as networks with non-transposed lines. Some of them are operated with additional earthing of faulted phase for increasing the safety in the point of the fault. The equipment of additional earthing of faulted phase is also able to connect healthy phase for short time. There are fast circuit breakers for additional earthing in the substation and the cycle close-open is shorter than time for tripping of an overcurrent protection in the outgoing feeder-bay (100ms). The paper deals with analysis of the touch voltages in the point of the fault during fault location and describes the experiment in real distribution netw (en)
Title
  • The Influence of Additional Earthing of Healthy Phase for Earth Fault Location on Safety of Compensated Networks
  • The Influence of Additional Earthing of Healthy Phase for Earth Fault Location on Safety of Compensated Networks (en)
skos:prefLabel
  • The Influence of Additional Earthing of Healthy Phase for Earth Fault Location on Safety of Compensated Networks
  • The Influence of Additional Earthing of Healthy Phase for Earth Fault Location on Safety of Compensated Networks (en)
skos:notation
  • RIV/00216305:26220/13:PU105853!RIV15-MSM-26220___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(ED0014/01/01), P(EE2.3.30.0005)
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 79656
http://linked.open...ai/riv/idVysledku
  • RIV/00216305:26220/13:PU105853
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • earth fault, safety, compensated network, earthing, location (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [75A43E43CD09]
http://linked.open...v/mistoKonaniAkce
  • Stockholm
http://linked.open...i/riv/mistoVydani
  • Stockholm (Sweden)
http://linked.open...i/riv/nazevZdroje
  • CIRED 2013 22nd International Conference on Electricity Distribution
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Dvořák, Jaromír
  • Toman, Petr
  • Orságová, Jaroslava
  • Topolánek, David
http://linked.open...vavai/riv/typAkce
http://linked.open.../riv/zahajeniAkce
number of pages
http://bibframe.org/vocab/doi
  • 10.1049/cp.2013.1173
http://purl.org/ne...btex#hasPublisher
  • CIRED
https://schema.org/isbn
  • 978-1-84919-732-8
http://localhost/t...ganizacniJednotka
  • 26220
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 48 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software