About: Zkratový proud v zatíženém synchronním generátoru     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • This paper deals with the short circuit current calculation of the load synchronous generator. The short circuit current equation is compounded of the three parts. The first part of the time behavior is a subtransient state, the second part is a transient state and the last part is a steady state. These states compose a total equation of short circuit current together and are calculated by a derivate equation on base of induced voltages, a d-q axis reactance and machine parameters. These currents are not a problem to measure in the small machines but these currents are easier to calculate in the machines with nominal power MVA and bigger. It is im-portant to know generator time constants and all reactances (d-q axis). The Induced voltages are derived from generator currents and voltages in this paper too.
  • This paper deals with the short circuit current calculation of the load synchronous generator. The short circuit current equation is compounded of the three parts. The first part of the time behavior is a subtransient state, the second part is a transient state and the last part is a steady state. These states compose a total equation of short circuit current together and are calculated by a derivate equation on base of induced voltages, a d-q axis reactance and machine parameters. These currents are not a problem to measure in the small machines but these currents are easier to calculate in the machines with nominal power MVA and bigger. It is im-portant to know generator time constants and all reactances (d-q axis). The Induced voltages are derived from generator currents and voltages in this paper too. (en)
  • This paper deals with the short circuit current calculation of the load synchronous generator. The short circuit current equation is compounded of the three parts. The first part of the time behavior is a subtransient state, the second part is a transient state and the last part is a steady state. These states compose a total equation of short circuit current together and are calculated by a derivate equation on base of induced voltages, a d-q axis reactance and machine parameters. These currents are not a problem to measure in the small machines but these currents are easier to calculate in the machines with nominal power MVA and bigger. It is im-portant to know generator time constants and all reactances (d-q axis). The Induced voltages are derived from generator currents and voltages in this paper too. (cs)
Title
  • Zkratový proud v zatíženém synchronním generátoru
  • Zkratový proud v zatíženém synchronním generátoru (cs)
  • Short Circuit Current in the Loaded Synchronous Generator (en)
skos:prefLabel
  • Zkratový proud v zatíženém synchronním generátoru
  • Zkratový proud v zatíženém synchronním generátoru (cs)
  • Short Circuit Current in the Loaded Synchronous Generator (en)
skos:notation
  • RIV/00216305:26220/12:PU98579!RIV13-MPO-26220___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(FR-TI1/068)
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 182502
http://linked.open...ai/riv/idVysledku
  • RIV/00216305:26220/12:PU98579
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • This paper deals with the short circuit current calculation of the load synchronous generator. The short circuit current equation is compounded of the three parts. The first part of the time behavior is a subtransient state, the second part is a transien (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [D83782614E02]
http://linked.open...v/mistoKonaniAkce
  • Brno
http://linked.open...i/riv/mistoVydani
  • Brno
http://linked.open...i/riv/nazevZdroje
  • Proccedings of the 13th International Scientific Conference Electric Power Engineering 2012
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Michailidis, Petr
http://linked.open...vavai/riv/typAkce
http://linked.open.../riv/zahajeniAkce
number of pages
http://purl.org/ne...btex#hasPublisher
  • VUT, FEKT, UEEN
https://schema.org/isbn
  • 978-80-214-4514-7
http://localhost/t...ganizacniJednotka
  • 26220
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 24 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software