About: Interpolace trojrozměrných dat magnetické rezonance     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • This article deals with three-dimensional reconstruction methods of nuclear magnetic resonance images. The testing images were observed by tomograph with basic magnetic field of 4.7 T at the Institute of Scientific Instruments (Academy of Sciences of the Czech Republic). There were acquired 10 slices of the testing phantom. There were found methods with the aim of getting utmost information about the shape of the testing phantom. One possible way is to increase the count of the sensed slices, but it implies decreasing of the signal to noise ratio. The second approach is finding the compromise between the effective count of slices and the following interpolation of other slices between the sensed ones. The both approaches were compared. The resultant images were segmented by the active contour methods which are based on partial differential equations solution [1], [2]. The advantage of these methods is that the images may not be preprocessed before segmentation. The appropriate segmented slices were co (en)
  • Pro posouzení kvality výstupního obrazu tomografu magnetické rezonance se můžeme nejčastěji setkat s určením poměru SNR. Bylo zjištěno, že zvyšováním počtu řezů snímaným objektem se zvyšuje příspěvek šumu ve výsledných obrazech - řezech. Je tedy nutné najít vhodný kompromis mezi dostačujícím počtem řezů objektem a vysokým poměrem SNR. Ze získaných obrazů můžeme vytvořit model snímaného objektu. Pro kvalitní rekonstrukci je třeba získat co nejvíce řezů. Článek popisuje možné přístupy interpolace dat mezi snímanými řezy. Aplikací popsané metody dostaneme více řezů a rekonstruovaný tvar snímaného objektu potom může dosahovat větší přesnosti.
  • Pro posouzení kvality výstupního obrazu tomografu magnetické rezonance se můžeme nejčastěji setkat s určením poměru SNR. Bylo zjištěno, že zvyšováním počtu řezů snímaným objektem se zvyšuje příspěvek šumu ve výsledných obrazech - řezech. Je tedy nutné najít vhodný kompromis mezi dostačujícím počtem řezů objektem a vysokým poměrem SNR. Ze získaných obrazů můžeme vytvořit model snímaného objektu. Pro kvalitní rekonstrukci je třeba získat co nejvíce řezů. Článek popisuje možné přístupy interpolace dat mezi snímanými řezy. Aplikací popsané metody dostaneme více řezů a rekonstruovaný tvar snímaného objektu potom může dosahovat větší přesnosti. (cs)
Title
  • Interpolace trojrozměrných dat magnetické rezonance
  • Interpolation of magnetic resonance threedimensional data (en)
  • Interpolace trojrozměrných dat magnetické rezonance (cs)
skos:prefLabel
  • Interpolace trojrozměrných dat magnetické rezonance
  • Interpolation of magnetic resonance threedimensional data (en)
  • Interpolace trojrozměrných dat magnetické rezonance (cs)
skos:notation
  • RIV/00216305:26220/10:PU85213!RIV11-MSM-26220___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(GA102/07/0389), S, Z(MSM0021630513)
http://linked.open...iv/cisloPeriodika
  • 14
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 264601
http://linked.open...ai/riv/idVysledku
  • RIV/00216305:26220/10:PU85213
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • interpolation, magnetic resonance, 3D reconstruction (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • CZ - Česká republika
http://linked.open...ontrolniKodProRIV
  • [A4985118D641]
http://linked.open...i/riv/nazevZdroje
  • Elektrorevue - Internetový časopis (http://www.elektrorevue.cz)
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 2010
http://linked.open...iv/tvurceVysledku
  • Mikulka, Jan
http://linked.open...n/vavai/riv/zamer
issn
  • 1213-1539
number of pages
http://localhost/t...ganizacniJednotka
  • 26220
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 47 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software