  • Reliable hydrogen sensors are essential to detect accidental hydrogen releases when hydrogen will be used to fuel future vehicles. To assess the performance of hydrogen safety sensors under conditions typical of automotive applications a test protocol has been defined. It has been experimentally evaluated by performing tests on commercially available hydrogen sensors. Catalytic sensors measured hydrogen concentration accurately and sensor response was largely independent of ambient parameters. However they were significantly cross sensitive to carbon monoxide and the detection limit was high. Metal-oxide semiconductive sensors had a low detection limit and showed a low cross sensitivity to carbon monoxide however almost all of these samples showed poor accuracy and a strong dependence on ambient parameters. Electrochemical sensors also had a low detection limit however ambient parameters, cross sensitivity and accuracy tests showed a high variation in results. Tests on a limited number of thermal cond
  • Reliable hydrogen sensors are essential to detect accidental hydrogen releases when hydrogen will be used to fuel future vehicles. To assess the performance of hydrogen safety sensors under conditions typical of automotive applications a test protocol has been defined. It has been experimentally evaluated by performing tests on commercially available hydrogen sensors. Catalytic sensors measured hydrogen concentration accurately and sensor response was largely independent of ambient parameters. However they were significantly cross sensitive to carbon monoxide and the detection limit was high. Metal-oxide semiconductive sensors had a low detection limit and showed a low cross sensitivity to carbon monoxide however almost all of these samples showed poor accuracy and a strong dependence on ambient parameters. Electrochemical sensors also had a low detection limit however ambient parameters, cross sensitivity and accuracy tests showed a high variation in results. Tests on a limited number of thermal cond (en)
Title
  • Reliability of commercially available hydrogen sensors for detection of hydrogen at critical concentrations: Part II selected sensor test results
  • Reliability of commercially available hydrogen sensors for detection of hydrogen at critical concentrations: Part II selected sensor test results (en)
skos:prefLabel
  • Reliability of commercially available hydrogen sensors for detection of hydrogen at critical concentrations: Part II selected sensor test results
  • Reliability of commercially available hydrogen sensors for detection of hydrogen at critical concentrations: Part II selected sensor test results (en)
skos:notation
  • RIV/00216305:26220/09:PU78897!RIV10-MSM-26220___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • Z(MSM0021630503)
http://linked.open...iv/cisloPeriodika
  • 1
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 338846
http://linked.open...ai/riv/idVysledku
  • RIV/00216305:26220/09:PU78897
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Hydrogen sensor, Hydrogen detection, Safety, Sensor performance testing (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • GB - Spojené království Velké Británie a Severního Irska
http://linked.open...ontrolniKodProRIV
  • [1F814648F3A1]
http://linked.open...i/riv/nazevZdroje
  • INTERNATIONAL JOURNAL OF HYDROGEN ENERGY
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 2008
http://linked.open...iv/tvurceVysledku
  • Boušek, Jaroslav
http://linked.open...n/vavai/riv/zamer
issn
  • 0360-3199
number of pages
http://localhost/t...ganizacniJednotka
  • 26220
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software