About: Bio-Assessing of Environmental Pollution via Monitoring of Metallothionein Level Using Electrochemical Detection     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • In this paper, we report on an investigation of affecting guppy fishes (Poecilia reticulata) by silver ions (0, 0.3, 0.6, 1.2, 2.5, and 5 mu M) for seven days under well-controlled experimental conditions. To observe the physiological changes, we attempted to determine metallothionein (MT) as a biomarker of heavy metal stress. For this purpose, we proposed a sensor utilizing a carbon electrode coupled with flow injection analysis. The experimental conditions, which have been optimized, were as follows-applied potential: 750 mV, mobile phase: Britton-Robinson buffer (pH 1.9) with How rate of 0.6 ml/min, time filter: 2.5 s, %22current R%22: 1 mu A. Under these conditions, the detection limit of MT was estimated as 100 pM. After the optimizing step, the fish tissues were measured. Based on the results obtained, MT content increased with increasing dose of silver ions and time of the treatment. The results obtained were in good correlation with those obtained by adsorptive transfer stripping technique coupled
  • In this paper, we report on an investigation of affecting guppy fishes (Poecilia reticulata) by silver ions (0, 0.3, 0.6, 1.2, 2.5, and 5 mu M) for seven days under well-controlled experimental conditions. To observe the physiological changes, we attempted to determine metallothionein (MT) as a biomarker of heavy metal stress. For this purpose, we proposed a sensor utilizing a carbon electrode coupled with flow injection analysis. The experimental conditions, which have been optimized, were as follows-applied potential: 750 mV, mobile phase: Britton-Robinson buffer (pH 1.9) with How rate of 0.6 ml/min, time filter: 2.5 s, %22current R%22: 1 mu A. Under these conditions, the detection limit of MT was estimated as 100 pM. After the optimizing step, the fish tissues were measured. Based on the results obtained, MT content increased with increasing dose of silver ions and time of the treatment. The results obtained were in good correlation with those obtained by adsorptive transfer stripping technique coupled (en)
Title
  • Bio-Assessing of Environmental Pollution via Monitoring of Metallothionein Level Using Electrochemical Detection
  • Bio-Assessing of Environmental Pollution via Monitoring of Metallothionein Level Using Electrochemical Detection (en)
skos:prefLabel
  • Bio-Assessing of Environmental Pollution via Monitoring of Metallothionein Level Using Electrochemical Detection
  • Bio-Assessing of Environmental Pollution via Monitoring of Metallothionein Level Using Electrochemical Detection (en)
skos:notation
  • RIV/00216305:26220/08:PU78016!RIV13-MSM-26220___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • I, P(GA526/07/0674), Z(MSM0021622412)
http://linked.open...iv/cisloPeriodika
  • 9-10
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 357993
http://linked.open...ai/riv/idVysledku
  • RIV/00216305:26220/08:PU78016
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Amperometric detection, biomarker, electrochemical sensors, fish, flow injection analysis, heavy metal, metallothionein, poecilia reticulata, silver (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • US - Spojené státy americké
http://linked.open...ontrolniKodProRIV
  • [21DD34E00C20]
http://linked.open...i/riv/nazevZdroje
  • IEEE SENSORS JOURNAL
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 8
http://linked.open...iv/tvurceVysledku
  • Adam, Vojtěch
  • Beklová, Miroslava
  • Hubálek, Jaromír
  • Kizek, René
  • Křížková, Soňa
  • Stejskal, Karel
  • Trnková, Libuše
  • Zehnálek, Josef
http://linked.open...n/vavai/riv/zamer
issn
  • 1530-437X
number of pages
http://localhost/t...ganizacniJednotka
  • 26220
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   