About: Image Improvement in Confocal Scanning Laser Ophthalmoscopy     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • We present a new approach for the reconstruction of intensity image from confocal scanning laser ophthalmoscope. Several procedures are used in the proposed approach including image registration, best-focus detection, filtering and 2D deconvolution.
  • We present a new approach for the reconstruction of intensity image from confocal scanning laser ophthalmoscope. Several procedures are used in the proposed approach including image registration, best-focus detection, filtering and 2D deconvolution. (en)
  • Představení nového přístupu pro rekonstrukci intenzitních obrazů z konfokálního laserového oftalmoskopu. Postup využívá registrace obrazů, filtrace a 2D dekonvoluce. (cs)
Title
  • Image Improvement in Confocal Scanning Laser Ophthalmoscopy
  • Zlepšování obrazů z konfokálního laserového oftalmoskopu (cs)
  • Image Improvement in Confocal Scanning Laser Ophthalmoscopy (en)
skos:prefLabel
  • Image Improvement in Confocal Scanning Laser Ophthalmoscopy
  • Zlepšování obrazů z konfokálního laserového oftalmoskopu (cs)
  • Image Improvement in Confocal Scanning Laser Ophthalmoscopy (en)
skos:notation
  • RIV/00216305:26220/06:PU60566!RIV08-MSM-26220___
http://linked.open.../vavai/riv/strany
  • 239-241
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(1M0572), Z(MSM0021630513)
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 478833
http://linked.open...ai/riv/idVysledku
  • RIV/00216305:26220/06:PU60566
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • confocal scanning laser ophthalmoscopy, image registration, image processing, 2D deconvolution (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [A1DBD7CA6422]
http://linked.open...v/mistoKonaniAkce
  • Brno
http://linked.open...i/riv/mistoVydani
  • Brno
http://linked.open...i/riv/nazevZdroje
  • Analysis of Biomedical Signals and Images
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Jan, Jiří
  • Jiřík, Radovan
  • Kolář, Radim
  • Kubečka, Libor
http://linked.open...vavai/riv/typAkce
http://linked.open.../riv/zahajeniAkce
http://linked.open...n/vavai/riv/zamer
number of pages
http://purl.org/ne...btex#hasPublisher
  • VUTIUM Press
https://schema.org/isbn
  • 80-214-3152-0
http://localhost/t...ganizacniJednotka
  • 26220
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 41 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software