About: Wide Current Range Potentiostat     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • In various sphere of industry like in medicine, in agriculture, in food-processing industry or in living environment is needed to recognize matters of analyte. Analyte is the matter we determine. To determining a matter in scaned solution we use sensors. A sensors made by thick film technology are the substrate for production of biosensors. Biosensor is analytical instrument containing sensitive element biological origin, which is part of it or in tight contact with physical-chemical convertor. It provides running electronical signal, which is commensurable to concentration one or some (group) of chemical matters in a sample. Acquired signal for next processing reach very small value of current or voltage. Measured current from microelectrodes reach values from pA to mA. Whole system is optimized for measuring these small values of magnitudes. For measuring is used method of cyclic voltammetry, where is analyzed current response on triangle input voltage. Current response is logarithmic so there is a
  • In various sphere of industry like in medicine, in agriculture, in food-processing industry or in living environment is needed to recognize matters of analyte. Analyte is the matter we determine. To determining a matter in scaned solution we use sensors. A sensors made by thick film technology are the substrate for production of biosensors. Biosensor is analytical instrument containing sensitive element biological origin, which is part of it or in tight contact with physical-chemical convertor. It provides running electronical signal, which is commensurable to concentration one or some (group) of chemical matters in a sample. Acquired signal for next processing reach very small value of current or voltage. Measured current from microelectrodes reach values from pA to mA. Whole system is optimized for measuring these small values of magnitudes. For measuring is used method of cyclic voltammetry, where is analyzed current response on triangle input voltage. Current response is logarithmic so there is a (en)
  • In various sphere of industry like in medicine, in agriculture, in food-processing industry or in living environment is needed to recognize matters of analyte. Analyte is the matter we determine. To determining a matter in scaned solution we use sensors. A sensors made by thick film technology are the substrate for production of biosensors. Biosensor is analytical instrument containing sensitive element biological origin, which is part of it or in tight contact with physical-chemical convertor. It provides running electronical signal, which is commensurable to concentration one or some (group) of chemical matters in a sample. Acquired signal for next processing reach very small value of current or voltage. Measured current from microelectrodes reach values from pA to mA. Whole system is optimized for measuring these small values of magnitudes. For measuring is used method of cyclic voltammetry, where is analyzed current response on triangle input voltage. Current response is logarithmic so there is a (cs)
Title
  • Wide Current Range Potentiostat
  • Potenciostat s velkým proudovým rozsahem (cs)
  • Wide Current Range Potentiostat (en)
skos:prefLabel
  • Wide Current Range Potentiostat
  • Potenciostat s velkým proudovým rozsahem (cs)
  • Wide Current Range Potentiostat (en)
skos:notation
  • RIV/00216305:26220/05:PU51305!RIV08-GA0-26220___
http://linked.open.../vavai/riv/strany
  • 21-24
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(FD-K2/53), P(GA102/03/0619), Z(MSM0021630503)
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 551429
http://linked.open...ai/riv/idVysledku
  • RIV/00216305:26220/05:PU51305
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • potentiostat, cyclic voltammetry, PC interface, (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [E9B818C64059]
http://linked.open...v/mistoKonaniAkce
  • Brno
http://linked.open...i/riv/mistoVydani
  • Brno
http://linked.open...i/riv/nazevZdroje
  • EDS '05 IMAPS CS International Conference Proceedings
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Havlíček, Tomáš
  • Boušek, Jaroslav
http://linked.open...vavai/riv/typAkce
http://linked.open.../riv/zahajeniAkce
http://linked.open...n/vavai/riv/zamer
number of pages
http://purl.org/ne...btex#hasPublisher
  • Vysoké učení technické v Brně
https://schema.org/isbn
  • 80-214-2990-9
http://localhost/t...ganizacniJednotka
  • 26220
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 77 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software