Attributes | Values |
---|
rdf:type
| |
Description
| - The biosensor signal analysis in portable microfluidic device [1] for organophosphorous pesticide toxicity analysis for field measurement is presented. Portable microfluidic device consists of two loop pumps. The first loop assures the mixing of solution. The 95 % of solution circulates through the first loop. The second loop consists of the capillary, which creates the hydrodynamic resistance, and of the chamber with biosensor. The 5 % of solution circulates through the second loop. The Artificial Synapsis (AS) [2] is integrated in the chamber with the biosensor. The AS detects the integral organophosphorous pesticide toxicity. Both parts are integrated in a compact device with size of 200 x 100 x 100 mm.
- The biosensor signal analysis in portable microfluidic device [1] for organophosphorous pesticide toxicity analysis for field measurement is presented. Portable microfluidic device consists of two loop pumps. The first loop assures the mixing of solution. The 95 % of solution circulates through the first loop. The second loop consists of the capillary, which creates the hydrodynamic resistance, and of the chamber with biosensor. The 5 % of solution circulates through the second loop. The Artificial Synapsis (AS) [2] is integrated in the chamber with the biosensor. The AS detects the integral organophosphorous pesticide toxicity. Both parts are integrated in a compact device with size of 200 x 100 x 100 mm. (en)
- V článku je prezentována analýza signálu v mikroprůtokovém zařízení. Mikroprůtokové zařízení spolu s biosenzorem je určeno k detekci toxicity pesticidů. V článku je popsán matematický model toku sustrátu a produktu v mikroprůtokovém zařízení. (cs)
|
Title
| - Analýza signálu z biosenzoru v přenosném mikroprůtokovém zařízení (cs)
- The Biosensor Signal Analysis in Portable Microfluidic Device
- The Biosensor Signal Analysis in Portable Microfluidic Device (en)
|
skos:prefLabel
| - Analýza signálu z biosenzoru v přenosném mikroprůtokovém zařízení (cs)
- The Biosensor Signal Analysis in Portable Microfluidic Device
- The Biosensor Signal Analysis in Portable Microfluidic Device (en)
|
skos:notation
| - RIV/00216305:26220/04:PU44781!RIV06-GA0-26220___
|
http://linked.open.../vavai/riv/strany
| |
http://linked.open...avai/riv/aktivita
| |
http://linked.open...avai/riv/aktivity
| - P(FD-K2/53), P(GA102/03/0619), P(GD102/03/H105), Z(MSM 262200022)
|
http://linked.open...iv/cisloPeriodika
| |
http://linked.open...vai/riv/dodaniDat
| |
http://linked.open...aciTvurceVysledku
| |
http://linked.open.../riv/druhVysledku
| |
http://linked.open...iv/duvernostUdaju
| |
http://linked.open...titaPredkladatele
| |
http://linked.open...dnocenehoVysledku
| |
http://linked.open...ai/riv/idVysledku
| - RIV/00216305:26220/04:PU44781
|
http://linked.open...riv/jazykVysledku
| |
http://linked.open.../riv/klicovaSlova
| - Compartmental analysis, Biosensor, Laplace transformation (en)
|
http://linked.open.../riv/klicoveSlovo
| |
http://linked.open...odStatuVydavatele
| |
http://linked.open...ontrolniKodProRIV
| |
http://linked.open...i/riv/nazevZdroje
| - WSEAS Transactions on Circuits
|
http://linked.open...in/vavai/riv/obor
| |
http://linked.open...ichTvurcuVysledku
| |
http://linked.open...cetTvurcuVysledku
| |
http://linked.open...vavai/riv/projekt
| |
http://linked.open...UplatneniVysledku
| |
http://linked.open...v/svazekPeriodika
| |
http://linked.open...iv/tvurceVysledku
| - Fujcik, Lukáš
- Vrba, Radimír
- Krejčí, Jan
|
http://linked.open...n/vavai/riv/zamer
| |
issn
| |
number of pages
| |
http://localhost/t...ganizacniJednotka
| |