About: Specific Conditions for EMI Filters Measuring     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • This paper deals with measuring EMI supply filters. There is explained the measuring configuration which is now design for the measuring of insertion loss of EMI filters. The main problem in this type of measuring is that the filter is normally designed for the constant input and output impedances which is usually 50 ohms. But the main question is what does it happen if we connect this filter into the low-voltage power supply network. So I designed the simple circuits which try to simulate the impedance of the low-voltage power supply network. And these circuits were used in measuring of the EMI supply filter. Now these circuits are designed only for measuring the asymmetric insertion loss and the life cycle of the output impedance is design in harmony with output impedance of the circuits which is very often called LISN (Line Impedance Stabilising Network). This circuit we can find in the measuring devices which are able to measure the interference that is circulated in network’s wires. Anyway, sev
  • This paper deals with measuring EMI supply filters. There is explained the measuring configuration which is now design for the measuring of insertion loss of EMI filters. The main problem in this type of measuring is that the filter is normally designed for the constant input and output impedances which is usually 50 ohms. But the main question is what does it happen if we connect this filter into the low-voltage power supply network. So I designed the simple circuits which try to simulate the impedance of the low-voltage power supply network. And these circuits were used in measuring of the EMI supply filter. Now these circuits are designed only for measuring the asymmetric insertion loss and the life cycle of the output impedance is design in harmony with output impedance of the circuits which is very often called LISN (Line Impedance Stabilising Network). This circuit we can find in the measuring devices which are able to measure the interference that is circulated in network’s wires. Anyway, sev (en)
Title
  • Specific Conditions for EMI Filters Measuring
  • Specific Conditions for EMI Filters Measuring (en)
skos:prefLabel
  • Specific Conditions for EMI Filters Measuring
  • Specific Conditions for EMI Filters Measuring (en)
skos:notation
  • RIV/00216305:26220/04:PU43978!RIV11-MSM-26220___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(GA102/04/1079), P(GD102/03/H109), V, Z(MSM 262200011)
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 587321
http://linked.open...ai/riv/idVysledku
  • RIV/00216305:26220/04:PU43978
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • EMC, Filter, Network Impedance (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [5F904262FBA3]
http://linked.open...v/mistoKonaniAkce
  • Manchester
http://linked.open...i/riv/mistoVydani
  • Manchester, Great Britain
http://linked.open...i/riv/nazevZdroje
  • 2004 High Frequency Postgraduate Student Colloquium
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Dřínovský, Jiří
  • Motl, Milan
http://linked.open...vavai/riv/typAkce
http://linked.open.../riv/zahajeniAkce
http://linked.open...n/vavai/riv/zamer
number of pages
http://purl.org/ne...btex#hasPublisher
  • UMIST, Manchester
https://schema.org/isbn
  • 0-7803-8426-1
http://localhost/t...ganizacniJednotka
  • 26220
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software