About: Wide Range Precise Conductivity Measurement without Cell Replacement     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • This paper a little contributes into precise electrolytic conductivity measurements with planar sensors. The novel measuring method was suggested for measurement with IDEs thick-film electrodes. Correction characteristics in wide range of a specific conductivity were determined from a interface impedance characterisation of the thick-film IDEs. The cell constant strongly depends on frequency and conductivity of solutions. A local minimum of the imaginary part of the interface impedance is used for correections to get linear responses. In this minimum a ridge frequency and a cell constant were determined for each measured conductivity. An iteration mode of measurements was suggested to measure exactly in the ridge frequency of the measured conductivity to rich high accurate response. A implementation of the method as microcontroller application can used to built-up microsystem for precise conductivity measurements in concentration range from 10-6 to 1 M without the cell replacement.
  • This paper a little contributes into precise electrolytic conductivity measurements with planar sensors. The novel measuring method was suggested for measurement with IDEs thick-film electrodes. Correction characteristics in wide range of a specific conductivity were determined from a interface impedance characterisation of the thick-film IDEs. The cell constant strongly depends on frequency and conductivity of solutions. A local minimum of the imaginary part of the interface impedance is used for correections to get linear responses. In this minimum a ridge frequency and a cell constant were determined for each measured conductivity. An iteration mode of measurements was suggested to measure exactly in the ridge frequency of the measured conductivity to rich high accurate response. A implementation of the method as microcontroller application can used to built-up microsystem for precise conductivity measurements in concentration range from 10-6 to 1 M without the cell replacement. (en)
  • This paper a little contributes into precise electrolytic conductivity measurements with planar sensors. The novel measuring method was suggested for measurement with IDEs thick-film electrodes. Correction characteristics in wide range of a specific conductivity were determined from a interface impedance characterisation of the thick-film IDEs. The cell constant strongly depends on frequency and conductivity of solutions. A local minimum of the imaginary part of the interface impedance is used for correections to get linear responses. In this minimum a ridge frequency and a cell constant were determined for each measured conductivity. An iteration mode of measurements was suggested to measure exactly in the ridge frequency of the measured conductivity to rich high accurate response. A implementation of the method as microcontroller application can used to built-up microsystem for precise conductivity measurements in concentration range from 10-6 to 1 M without the cell replacement. (cs)
Title
  • Wide Range Precise Conductivity Measurement without Cell Replacement
  • Wide Range Precise Conductivity Measurement without Cell Replacement (en)
  • Wide Range Precise Conductivity Measurement without Cell Replacement (cs)
skos:prefLabel
  • Wide Range Precise Conductivity Measurement without Cell Replacement
  • Wide Range Precise Conductivity Measurement without Cell Replacement (en)
  • Wide Range Precise Conductivity Measurement without Cell Replacement (cs)
skos:notation
  • RIV/00216305:26220/02:PU29928!RIV06-GA0-26220___
http://linked.open.../vavai/riv/strany
  • 1-4
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(GA102/00/0939), Z(MSM 262200022)
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 670770
http://linked.open...ai/riv/idVysledku
  • RIV/00216305:26220/02:PU29928
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Thick-film sensors, conductivity, iterative method, frequency tuning (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [2E84E92B6CB0]
http://linked.open...v/mistoKonaniAkce
  • Praha
http://linked.open...i/riv/mistoVydani
  • Praha
http://linked.open...i/riv/nazevZdroje
  • Proceedings of Conference Eurosensors XVI
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Hubálek, Jaromír
  • Krejčí, Jan
http://linked.open...vavai/riv/typAkce
http://linked.open.../riv/zahajeniAkce
http://linked.open...n/vavai/riv/zamer
number of pages
http://purl.org/ne...btex#hasPublisher
  • České vysoké učení technické v Praze
http://localhost/t...ganizacniJednotka
  • 26220
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software