About: Wide Range Precise Conductivity Measurement without Cell Replacement     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • The paper present new approach in the field of precise electrolytic conductivity measurements with planar sensors. This novel measuring method was suggested for measurement with IDEs thick-film electrodes. Correction characteristics over a wide range of a specific conductivities were determined from an interface impedance characterisation of the thick-film IDEs. A local minimum of the imaginary part of the interface impedance is used for corrections to get linear responses. The ridge frequency was deterrmined at wide range of measured conductivity. An iteration mode of measurements was suggested to exactly measure the conductivity in the ridge frequency in order to achieve a highly accurate response. The method takes precise conductivity measurements in concentration ranges from 10-6 to 1 M without cell replacement.
  • The paper present new approach in the field of precise electrolytic conductivity measurements with planar sensors. This novel measuring method was suggested for measurement with IDEs thick-film electrodes. Correction characteristics over a wide range of a specific conductivities were determined from an interface impedance characterisation of the thick-film IDEs. A local minimum of the imaginary part of the interface impedance is used for corrections to get linear responses. The ridge frequency was deterrmined at wide range of measured conductivity. An iteration mode of measurements was suggested to exactly measure the conductivity in the ridge frequency in order to achieve a highly accurate response. The method takes precise conductivity measurements in concentration ranges from 10-6 to 1 M without cell replacement. (en)
  • The paper present new approach in the field of precise electrolytic conductivity measurements with planar sensors. This novel measuring method was suggested for measurement with IDEs thick-film electrodes. Correction characteristics over a wide range of a specific conductivities were determined from an interface impedance characterisation of the thick-film IDEs. A local minimum of the imaginary part of the interface impedance is used for corrections to get linear responses. The ridge frequency was deterrmined at wide range of measured conductivity. An iteration mode of measurements was suggested to exactly measure the conductivity in the ridge frequency in order to achieve a highly accurate response. The method takes precise conductivity measurements in concentration ranges from 10-6 to 1 M without cell replacement. (cs)
Title
  • Wide Range Precise Conductivity Measurement without Cell Replacement
  • Wide Range Precise Conductivity Measurement without Cell Replacement (en)
  • Wide Range Precise Conductivity Measurement without Cell Replacement (cs)
skos:prefLabel
  • Wide Range Precise Conductivity Measurement without Cell Replacement
  • Wide Range Precise Conductivity Measurement without Cell Replacement (en)
  • Wide Range Precise Conductivity Measurement without Cell Replacement (cs)
skos:notation
  • RIV/00216305:26220/02:PU29223!RIV06-GA0-26220___
http://linked.open.../vavai/riv/strany
  • 602-603
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(FD-K2/53), P(GA102/00/0939), Z(MSM 262200022)
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 670771
http://linked.open...ai/riv/idVysledku
  • RIV/00216305:26220/02:PU29223
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • IDEs, electrolytic conductivity, iterative measurement, ridge frequency (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [2B3C19EC6114]
http://linked.open...v/mistoKonaniAkce
  • Praha
http://linked.open...i/riv/mistoVydani
  • FEL CVUT Praha
http://linked.open...i/riv/nazevZdroje
  • Eurosensors XVI, The 16th European Conference on Solid-State Transducers
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Hubálek, Jaromír
  • Krejčí, Jan
http://linked.open...vavai/riv/typAkce
http://linked.open.../riv/zahajeniAkce
http://linked.open...n/vavai/riv/zamer
number of pages
http://purl.org/ne...btex#hasPublisher
  • České vysoké učení technické v Praze. Fakulta elektrotechnická. Katedra měření
https://schema.org/isbn
  • 80-01-02576-4
http://localhost/t...ganizacniJednotka
  • 26220
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software