| - A sensor miniaturization brings many problems e.g. an effect of the double layer capacitance, a serial resistance of electrodes, a cell constant, a roughness of electrodes etc. Nowadays, an interdigitated electrodes (IDES) are used in many sensor's applications [3,4,5]. Interdigitated electrodes have a comb structure of electrode system and are deposited on an substrate in planar technology as the thick-film or the thin-film. In most cases good results were achieved using differential or transient measuurements. Measurement of frequency characteristics is not possible without a correction of the cell constant. Results of our current research show many problems with the behavioural of chemical cells if the comb structure with small sizes is used. Our results show that conductivity measurements need corrections of the cell constant for each concentration of a liquid solution. This paper investigates how sizes of IDES electrodes influence the interface impedance. Variation of the cell size can show possi
- A sensor miniaturization brings many problems e.g. an effect of the double layer capacitance, a serial resistance of electrodes, a cell constant, a roughness of electrodes etc. Nowadays, an interdigitated electrodes (IDES) are used in many sensor's applications [3,4,5]. Interdigitated electrodes have a comb structure of electrode system and are deposited on an substrate in planar technology as the thick-film or the thin-film. In most cases good results were achieved using differential or transient measuurements. Measurement of frequency characteristics is not possible without a correction of the cell constant. Results of our current research show many problems with the behavioural of chemical cells if the comb structure with small sizes is used. Our results show that conductivity measurements need corrections of the cell constant for each concentration of a liquid solution. This paper investigates how sizes of IDES electrodes influence the interface impedance. Variation of the cell size can show possi (en)
|
Title
| - Characterization of thick-film interdigitated electrodes
- Characterization of thick-film interdigitated electrodes (en)
|
skos:prefLabel
| - Characterization of thick-film interdigitated electrodes
- Characterization of thick-film interdigitated electrodes (en)
|
skos:notation
| - RIV/00216305:26220/01:PU27730!RIV/2002/GA0/262202/N
|
http://linked.open.../vavai/riv/strany
| |
http://linked.open...avai/riv/aktivita
| |
http://linked.open...avai/riv/aktivity
| |
http://linked.open...vai/riv/dodaniDat
| |
http://linked.open...aciTvurceVysledku
| |
http://linked.open.../riv/druhVysledku
| |
http://linked.open...iv/duvernostUdaju
| |
http://linked.open...titaPredkladatele
| |
http://linked.open...dnocenehoVysledku
| |
http://linked.open...ai/riv/idVysledku
| - RIV/00216305:26220/01:PU27730
|
http://linked.open...riv/jazykVysledku
| |
http://linked.open.../riv/klicovaSlova
| - Interface impedance, Double layer capacitance, cell constant correction (en)
|
http://linked.open.../riv/klicoveSlovo
| |
http://linked.open...ontrolniKodProRIV
| |
http://linked.open...v/mistoKonaniAkce
| |
http://linked.open...i/riv/mistoVydani
| |
http://linked.open...i/riv/nazevZdroje
| - th Electronic Devices and Systems Conference 2001 and Noise and Non-linearity Testing of modern Electronics Component
|
http://linked.open...in/vavai/riv/obor
| |
http://linked.open...ichTvurcuVysledku
| |
http://linked.open...cetTvurcuVysledku
| |
http://linked.open...ocetUcastnikuAkce
| |
http://linked.open...nichUcastnikuAkce
| |
http://linked.open...vavai/riv/projekt
| |
http://linked.open...UplatneniVysledku
| |
http://linked.open...iv/tvurceVysledku
| - Hubálek, Jaromír
- Krejčí, Jan
- Bulva, Jindřich
|