About: Computing Cooling Intensity from Descaling Experiments     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • Steel oxidation during the hot rolling in-line process is undesirable behavior. High pressure descaling nozzles are often used to remove oxides from the surface of a product. The water spray from high pressure nozzles also causes intense cooling. Knowledge of this cooling intensity is necessary for on-line simulations used by control systems. Knowledge of boundary conditions can also help with the choice of descaling nozzles. These boundary conditions are surface temperature, surface heat flux and the heat transfer coefficient (HTC). The HTC can be obtained from the measured temperature histories inside a test plate by inverse heat conduction problem or from the measured surface temperatures. This article describes a new inverse method for the computation of HTCs from surface temperature measurements using an infrared line-scanner during descaling experiments. The measurement technique used to obtain data for the inverse method is described as well. Data from real measurements are presented and evalua
  • Steel oxidation during the hot rolling in-line process is undesirable behavior. High pressure descaling nozzles are often used to remove oxides from the surface of a product. The water spray from high pressure nozzles also causes intense cooling. Knowledge of this cooling intensity is necessary for on-line simulations used by control systems. Knowledge of boundary conditions can also help with the choice of descaling nozzles. These boundary conditions are surface temperature, surface heat flux and the heat transfer coefficient (HTC). The HTC can be obtained from the measured temperature histories inside a test plate by inverse heat conduction problem or from the measured surface temperatures. This article describes a new inverse method for the computation of HTCs from surface temperature measurements using an infrared line-scanner during descaling experiments. The measurement technique used to obtain data for the inverse method is described as well. Data from real measurements are presented and evalua (en)
Title
  • Computing Cooling Intensity from Descaling Experiments
  • Computing Cooling Intensity from Descaling Experiments (en)
skos:prefLabel
  • Computing Cooling Intensity from Descaling Experiments
  • Computing Cooling Intensity from Descaling Experiments (en)
skos:notation
  • RIV/00216305:26210/13:PU105663!RIV14-MSM-26210___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(ED0002/01/01), P(EE2.3.20.0188)
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 66617
http://linked.open...ai/riv/idVysledku
  • RIV/00216305:26210/13:PU105663
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Cooling intensity, descaling, heat transfer coefficient, heat conduction task, infrared line-scanner (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [2EE3D178E6D4]
http://linked.open...v/mistoKonaniAkce
  • Ostrava
http://linked.open...i/riv/mistoVydani
  • Neuveden
http://linked.open...i/riv/nazevZdroje
  • Steelsim 2013
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Ondroušková, Jana
  • Pohanka, Michal
  • Komínek, Jan
http://linked.open...vavai/riv/typAkce
http://linked.open.../riv/zahajeniAkce
number of pages
http://purl.org/ne...btex#hasPublisher
  • Neuveden
https://schema.org/isbn
  • 978-80-260-3912-9
http://localhost/t...ganizacniJednotka
  • 26210
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software