About: Correlation between 3D imaging methods in studying bone architecture: SEM, microCT and confocal LM     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • Computerised x-ray microtomography (microCT) is increasingly used in the 3D study of bone microarchitecture and in quantifying bone volume fractions. However, the volumetric resolution in labora- tory apparatus for small rodent studies is at best several microns linear and recognisable detail characterising forming, resting and resorbing surfaces is completely missing. Backscattered electron mode scanning electron microscopy (BSE SEM) of both macerated 3D samples and polished surfaces of blocks of PMMA embedded tissue provides this information but samples have to be cut and processed. The same PMMA material is good for confocal fluores- cence microscopy (CSLM) for both tissue morphology and the study of tetracycline and calcein mineralising front labels to 50– 200 microns deep to the block surface. With the recent acquisi- tion of SEM with variable chamber pressure to permit examina- tion of uncoated specimens, we are able to conduct CSLM after SEM for correlation studies. Here, we report new approa
  • Computerised x-ray microtomography (microCT) is increasingly used in the 3D study of bone microarchitecture and in quantifying bone volume fractions. However, the volumetric resolution in labora- tory apparatus for small rodent studies is at best several microns linear and recognisable detail characterising forming, resting and resorbing surfaces is completely missing. Backscattered electron mode scanning electron microscopy (BSE SEM) of both macerated 3D samples and polished surfaces of blocks of PMMA embedded tissue provides this information but samples have to be cut and processed. The same PMMA material is good for confocal fluores- cence microscopy (CSLM) for both tissue morphology and the study of tetracycline and calcein mineralising front labels to 50– 200 microns deep to the block surface. With the recent acquisi- tion of SEM with variable chamber pressure to permit examina- tion of uncoated specimens, we are able to conduct CSLM after SEM for correlation studies. Here, we report new approa (en)
Title
  • Correlation between 3D imaging methods in studying bone architecture: SEM, microCT and confocal LM
  • Correlation between 3D imaging methods in studying bone architecture: SEM, microCT and confocal LM (en)
skos:prefLabel
  • Correlation between 3D imaging methods in studying bone architecture: SEM, microCT and confocal LM
  • Correlation between 3D imaging methods in studying bone architecture: SEM, microCT and confocal LM (en)
skos:notation
  • RIV/00216305:26210/12:PU99555!RIV13-MSM-26210___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • I
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 128856
http://linked.open...ai/riv/idVysledku
  • RIV/00216305:26210/12:PU99555
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • x-ray microtomography,scanning electron microscopy,confocal fluorescence microscopy,rat femur (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [ED72F99AC9C0]
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Zikmund, Tomáš
  • Boyde, Alan
  • Kvasnica, Lukáš
http://localhost/t...ganizacniJednotka
  • 26210
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 25 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software