About: Stress corrosion of partially immersed heat exchanger u-tubes     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • In general, every heat exchanger is designed individually. Various aspects, such as inlet and outlet temperatures, flow rates and stream pressures are considered in design process. Pursuit of optimal reliable design, tailored to specific needs is necessary for manufacturers in order to keep up with competition. However, optimal design can be very sensitive to changes in working conditions. In this paper, stress corrosion cracking of heat exchanger u-tubes as a consequence of decreased medium level in shell space is presented. Object of the study is heat exchanger with u-tubes used in petroleum industry. There is a mixture of gas oil and hydrogen in tube space. This mixture also contains sulphur chloride and ammonia therefore corrosion aided stress cracking presents serious threat. Inlet temperature is 350 C and medium flows at the pressure of 4.27 MPa. Shell space is partially filled with cooling water pressurized to 0.88 MPa, which is turned into steam with outlet temperature up to 200 C. At previous
  • In general, every heat exchanger is designed individually. Various aspects, such as inlet and outlet temperatures, flow rates and stream pressures are considered in design process. Pursuit of optimal reliable design, tailored to specific needs is necessary for manufacturers in order to keep up with competition. However, optimal design can be very sensitive to changes in working conditions. In this paper, stress corrosion cracking of heat exchanger u-tubes as a consequence of decreased medium level in shell space is presented. Object of the study is heat exchanger with u-tubes used in petroleum industry. There is a mixture of gas oil and hydrogen in tube space. This mixture also contains sulphur chloride and ammonia therefore corrosion aided stress cracking presents serious threat. Inlet temperature is 350 C and medium flows at the pressure of 4.27 MPa. Shell space is partially filled with cooling water pressurized to 0.88 MPa, which is turned into steam with outlet temperature up to 200 C. At previous (en)
Title
  • Stress corrosion of partially immersed heat exchanger u-tubes
  • Stress corrosion of partially immersed heat exchanger u-tubes (en)
skos:prefLabel
  • Stress corrosion of partially immersed heat exchanger u-tubes
  • Stress corrosion of partially immersed heat exchanger u-tubes (en)
skos:notation
  • RIV/00216305:26210/10:PU87932!RIV11-MSM-26210___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(2B08048)
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 290333
http://linked.open...ai/riv/idVysledku
  • RIV/00216305:26210/10:PU87932
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • heat exchanger, u-tube, thermal analysis, stress analysis (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [2CD3A5B53949]
http://linked.open...v/mistoKonaniAkce
  • Praha
http://linked.open...i/riv/mistoVydani
  • Praha
http://linked.open...i/riv/nazevZdroje
  • Materials of the 19th International Congress of Chemical and Process Engineering CHISA 2010 and the 7th European Congress of Chemical Engineering ECCE-7
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Létal, Tomáš
  • Nekvasil, Richard
http://linked.open...vavai/riv/typAkce
http://linked.open.../riv/zahajeniAkce
number of pages
http://purl.org/ne...btex#hasPublisher
  • Process Engineering Publisher
https://schema.org/isbn
  • 978-80-02-02248-0
http://localhost/t...ganizacniJednotka
  • 26210
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software