Attributes | Values |
---|
rdf:type
| |
Description
| - We prepared experimental measurement for detection of mechanical properties of vertebral element with applied MACS implant where we applied cyclic combination load (tension + torsion). Tension load was by constant force. Torsion load was deformation; itwas by measurement process function of time. The measurement was made for compact vertebral element, disturbed vertebral element and disturbed vertebral element with MACS. We measured a torsion moment which we have to make for torsioal displacement fi =5°. For the measurement was used pigs vertebral element.
- We prepared experimental measurement for detection of mechanical properties of vertebral element with applied MACS implant where we applied cyclic combination load (tension + torsion). Tension load was by constant force. Torsion load was deformation; itwas by measurement process function of time. The measurement was made for compact vertebral element, disturbed vertebral element and disturbed vertebral element with MACS. We measured a torsion moment which we have to make for torsioal displacement fi =5°. For the measurement was used pigs vertebral element. (en)
- Článek se zabývá experimentálním měřením mechanických vlastností páteřního prvku s aplikovaným fixátorem MACS. Vzorek byl zatěžován cyklickým zatížením (tah+torze). Měření bylo provedeno pro neporušený, porušený obratel a pro obratel s aplikovaným fixátorem. (cs)
|
Title
| - Experimental detection of mechanical properties of vertebral element with applied MACS TL-Twin Screw Implant
- Experimental detection of mechanical properties of vertebral element with applied MACS TL-Twin Screw Implant (en)
- Experimentální určování mechanických vlastností páteřních prvků s aplikovaným fixátorem MACS TL-Twin Screw Implant (cs)
|
skos:prefLabel
| - Experimental detection of mechanical properties of vertebral element with applied MACS TL-Twin Screw Implant
- Experimental detection of mechanical properties of vertebral element with applied MACS TL-Twin Screw Implant (en)
- Experimentální určování mechanických vlastností páteřních prvků s aplikovaným fixátorem MACS TL-Twin Screw Implant (cs)
|
skos:notation
| - RIV/00216305:26210/04:PU47613!RIV06-GA0-26210___
|
http://linked.open.../vavai/riv/strany
| |
http://linked.open...avai/riv/aktivita
| |
http://linked.open...avai/riv/aktivity
| - P(GA101/01/0974), Z(MSM 262100024)
|
http://linked.open...vai/riv/dodaniDat
| |
http://linked.open...aciTvurceVysledku
| |
http://linked.open.../riv/druhVysledku
| |
http://linked.open...iv/duvernostUdaju
| |
http://linked.open...titaPredkladatele
| |
http://linked.open...dnocenehoVysledku
| |
http://linked.open...ai/riv/idVysledku
| - RIV/00216305:26210/04:PU47613
|
http://linked.open...riv/jazykVysledku
| |
http://linked.open.../riv/klicovaSlova
| - experimental modelling, vertebral element, implant, MACS TL - Twin Screw (en)
|
http://linked.open.../riv/klicoveSlovo
| |
http://linked.open...ontrolniKodProRIV
| |
http://linked.open...v/mistoKonaniAkce
| |
http://linked.open...i/riv/mistoVydani
| |
http://linked.open...i/riv/nazevZdroje
| - Experimental Stress Analysis 2004
|
http://linked.open...in/vavai/riv/obor
| |
http://linked.open...ichTvurcuVysledku
| |
http://linked.open...cetTvurcuVysledku
| |
http://linked.open...vavai/riv/projekt
| |
http://linked.open...UplatneniVysledku
| |
http://linked.open...iv/tvurceVysledku
| - Florian, Zdeněk
- Návrat, Tomáš
- Tošovský, Jiří
|
http://linked.open...vavai/riv/typAkce
| |
http://linked.open.../riv/zahajeniAkce
| |
http://linked.open...n/vavai/riv/zamer
| |
number of pages
| |
http://purl.org/ne...btex#hasPublisher
| - Czech Society for Mechanics, branch Plzeň, ŠKODA VÝZKUM s.r.o.
|