About: ICP-oTOF-MS ANALYSIS OF PLATINUM IN ALGAE AND HOSPITAL WASTEWATER     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • The ICP-oTOF-MS (orthogonal time-of-flight inductively coupled plasma mass spectrometry) and ICP-OES (inductively coupled plasma optical emission spectrometry) methods were evaluated with regard to their possible use for determination of Pt in hospital wastewater and algae Parachlorella kessleri gained from laboratory growth experiments. A way of sample preparation of algae prior analysis was optimised. For the ICP-oTOF-MS method (internal standard Rh 10 mu g L-1), instrumental LODs (limits of detection) were obtained on isotopes Pt-194 195 196 0.0241-0.0338 mu g L-1, procedural LODs for algae samples 0.121-0.169 mg kg(-1) and for WWTP (wastewater treatment plant) samples 0.0525-0.0845 mu g L-1. The ICP-oTOF-MS method was proved to be suitable for monitoring of Pt in algae and wastewater samples. The ICP-OES (Pt 214.42 nm) procedural LOD for algae samples 2.38 mg kg(-1) (instrumental LOD 4.76 mu g L-1) did not meet concentrations in algae from growth experiments. Pt in the WWTP wastewaters samples was followed without any preconcentration step. Lower concentrations were found in the WWTP output than in the input. Based on Pt in algae growth experiments, BCFs (bioconcentration factors) were estimated according to Pt species presented: 440-610 ((NH4)(2)PtCl6), 690-1440 (the WWTP input) and 2510-2930 (the WWTP output), all in L kg(-1).
  • The ICP-oTOF-MS (orthogonal time-of-flight inductively coupled plasma mass spectrometry) and ICP-OES (inductively coupled plasma optical emission spectrometry) methods were evaluated with regard to their possible use for determination of Pt in hospital wastewater and algae Parachlorella kessleri gained from laboratory growth experiments. A way of sample preparation of algae prior analysis was optimised. For the ICP-oTOF-MS method (internal standard Rh 10 mu g L-1), instrumental LODs (limits of detection) were obtained on isotopes Pt-194 195 196 0.0241-0.0338 mu g L-1, procedural LODs for algae samples 0.121-0.169 mg kg(-1) and for WWTP (wastewater treatment plant) samples 0.0525-0.0845 mu g L-1. The ICP-oTOF-MS method was proved to be suitable for monitoring of Pt in algae and wastewater samples. The ICP-OES (Pt 214.42 nm) procedural LOD for algae samples 2.38 mg kg(-1) (instrumental LOD 4.76 mu g L-1) did not meet concentrations in algae from growth experiments. Pt in the WWTP wastewaters samples was followed without any preconcentration step. Lower concentrations were found in the WWTP output than in the input. Based on Pt in algae growth experiments, BCFs (bioconcentration factors) were estimated according to Pt species presented: 440-610 ((NH4)(2)PtCl6), 690-1440 (the WWTP input) and 2510-2930 (the WWTP output), all in L kg(-1). (en)
Title
  • ICP-oTOF-MS ANALYSIS OF PLATINUM IN ALGAE AND HOSPITAL WASTEWATER
  • ICP-oTOF-MS ANALYSIS OF PLATINUM IN ALGAE AND HOSPITAL WASTEWATER (en)
skos:prefLabel
  • ICP-oTOF-MS ANALYSIS OF PLATINUM IN ALGAE AND HOSPITAL WASTEWATER
  • ICP-oTOF-MS ANALYSIS OF PLATINUM IN ALGAE AND HOSPITAL WASTEWATER (en)
skos:notation
  • RIV/00216275:25310/14:39898088!RIV15-MSM-25310___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • S
http://linked.open...iv/cisloPeriodika
  • 3
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 20214
http://linked.open...ai/riv/idVysledku
  • RIV/00216275:25310/14:39898088
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • hospital wastewater; ICP-OES; ICP-oTOF-MS; bioconcentration factor; Parachlorella kessleri; alga (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • CZ - Česká republika
http://linked.open...ontrolniKodProRIV
  • [66B6547FC3B7]
http://linked.open...i/riv/nazevZdroje
  • Chemické listy
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 108
http://linked.open...iv/tvurceVysledku
  • Krejčová, Anna
  • Černohorský, Tomáš
  • Bendakovská, Lenka
  • Zvoníčková, Kateřina
http://linked.open...ain/vavai/riv/wos
  • 000346508500001
issn
  • 0009-2770
number of pages
http://localhost/t...ganizacniJednotka
  • 25310
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software